AICB up to 24 fibers tight buffered armoured SHF2 MUD NEK606, Fire Retardant IEC60332-3-22 Cat.A

Up to 24 cores tight buffered, metallic armoured SHF2, MUD Resistant NEK606, Fire Retardant IEC60332-3-22 Cat.A
OAICI0_U, 05.11.2014/AP rev.3
Type Approval: DNV-GL TAE00000UF






Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 15 times O.D.
Operate at : -30 to +70 °CBend minimum : 10 times O.D.
Crush maximum : 2000N/100mm
Impact maximum : 25J



Bare fiber : 250µm
Buffer : 900µm tight buffer
Colour code : See table
Cable core : up to 24 tight buffered fibers are stranded together. The core is filled with waterblocking glass yarns.
Inner sheath : black SHF1 material
Armour : galvanized steel, bronze or tinnerd copper wired braid. Coverage ≥80%.
Outer jacket : black MUD Resistant SHF2 material, UV-Resistant, LSZH
Marking : APS Finland – ww/mm – Fiber Optic Cable AICB “fiber count and type” – SHF1 IEC60332-3-22 Cat A – TK/lot + meter


Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
Weather resistant : YES – ASTM G 154, EN 11507
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact : CSA C22.2



Ordering and delivery information

Fiber countSMOM1OM2OM3OM4Packaging
2OAICB02S21OAICB02M11OAICB02M21OAICB02M31OAICB02M41drum 2000m (+/-5%)
4OAICB04S21OAICB04M11OAICB04M21OAICB04M31OAICB04M41drum 2000m (+/-5%)
8OAICB08S21OAICB08M11OAICB08M21OAICB08M31OAICB08M41drum 2000m (+/-5%)
12OAICB12S21OAICB12M11OAICB12M21OAICB12M31OAICB12M41drum 2000m (+/-5%)
24OAICB24S21OAICB24M11OAICB24M21OAICB24M31OAICB24M41drum 2000m (+/-5%)

Note : for bronze braid add “B” at the end of the P/N, for tinned copper braid add “T” at the end of the P/N.


Colour code of fibers





Fiber countInner jacket thickness (mm)Inner jacket diameter (mm)Outer jacket thickness (mm)Cable Diameter (mm)Cable weight (kg/km)Pulling tension (N)



Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1Type Approval Program - Optical Fibre Cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables
Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.