Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wa_wcc_txt domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/vhosts/aps-finland.fi/httpdocs/wp-includes/functions.php on line 6131
50 Ohm coaxial cable RG213 PVC MIL Norm - APS Finland

50 Ohm coaxial cable RG213 PVC MIL Norm

Non-armoured and armoured, PVC
RG213UMV, 30.03.2022/AP rev.0

 

Print or Download PDF

Description

  

 

 

Store at: -0 to +60 °C
Install at: 0 to +50 °CBend minimum: 10xO.D. (non-armoured), 20xO.D. (armoured) 
Operate at: -20 to +60 °CBend minimum: 15xO.D. (non-armoured), 20xO.D. (armoured)  

 

 

Design

Conductor : bare copper 7×0.75mm 
Dielectric : polyethylene nominal Ø 7.25mm
Screen : bare copper wire braid (coverage 96%) 
Outer jacket : black PVC material
Marking : APS Finland – ww/yy – M-17/74 RG213 U MIL-C-17F – 50 OHM – P/N – lot + meter

Armoured version is supplied with additional:
Armour : galvanized steel or tinned copper wire braid
Outer jacket : black PVC material
Marking : APS Finland – ww/yy – ARMOURED M-17/74 RG213 U MIL-C-17F – 50 OHM – P/N – lot + meter

 

Electrical characteristics

Impedance : 50 ± 3 ᘯ 
Capacitance : 101pF/m nominal
Velocity ratio : 65%
Insulation resistance :  10000 MΩ x Km

Spark tension of the sheath : 2.0 kV

 

Attenuation (typical)
MHz100200400600800100015002000300052005800
dB7.211.015.521.025.029.033.037.547.663.268.5

 

Ordering and delivery information

TypeP/NO.D [mm]Weight [kg/km]Packaging
RG213U PVC Non-armouredRG213UMV10.3160500m or 1000m (+/-5%)
RG213U PVC armoured GSWB RG213UMVBV14.6250500m (+/-5%)
RG213U PVC armoured TCWB RG213UMVTV14.6235500m (+/-5%)

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, APS Cables & Connectors Oy cannot be considered responsible for any mistake in this document and users should consult APS Cables & Connectors Oy for any information needed. APS Cables & Connectors Oy reserves the right to make changes to the documents at any time, without prior notice.