Description
Store at: -0 to +60 °C
Install at: 0 to +50 °C, Bend minimum: 10xO.D. (unarmored) or 20xO.D. (armored)
Operate at: -20 to +70 °C, Bend minimum: 15xO.D. (unarmored) or 20xO.D. (armored)
Design
Conductor : bare copper 7×0.76mm
Dielectric : polyethylene nominal Ø 7.25mm
Screen : bare copper wire braid
Outer jacket : black LSZH material
Marking : APS Finland – ww/yy – RG 213 type MIL LSZH – 50 OHM – P/N – lot + meter
Armoured version is supplied with additional:
Armour : galvanized steel or tinned copper wire braid
Outer jacket : black LSZH material
Marking : APS Finland – ww/yy – ARMOURED RG 213 type MIL LSZH – 50 OHM – P/N – lot + meter
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2
Halogen acid gas corrosiveness : TS EN 50267-2-3
Smoke Emission : IEC 61034-2
Flame retardant : IEC 60332-1-1, IEC60332-2-1
Electrical characteristics
Impedance : 50 ± 3 ᘯ
Capacitance : 101pF/m nominal
Velocity ratio : 66%
Insulation resistance : 10000 MΩ x Km
Spark tension of the sheath : 2.0 kV
Attenuation (typical)
MHz 100 200 400 600 800 1000 1500 2000 3000 5200 5800
dB 7.2 11.0 15.5 21.0 25.0 29.0 33.0 37.5 47.6 63.2 68.5
Ordering and delivery information
Type | P/N | O.D [mm] | Weight [kg/km] | Packaging | |
---|---|---|---|---|---|
RG213 Non-armoured | RG213MT | 10.2 | 163 | 500m or 1000m (+/-5%) | |
RG213 armoured GSWB | RG213MTBH | 14.5 | 250 | 500m (+/-5%) | |
RG213 armoured TCWB | RG213MTTH | 14.5 | 235 | 500m (+/-5%) |
Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.