50 Ohm coaxial cable RG213 LSZH MIL Type

Non-armoured and armoured LSZH, Flame Retardant IEC60332-1
RG213MT, 23.11.2017/AP rev.1

 

Print or Download PDF

Description

  

 

 

Store at: -0 to +60 °C
Install at: 0 to +50 °CBend minimum: 10xO.D. (unarmored) or 20xO.D. (armored)
Operate at: -20 to +70 °CBend minimum: 15xO.D. (unarmored) or 20xO.D. (armored)

 

 

Design

Conductor : bare copper 7×0.76mm 
Dielectric : polyethylene nominal Ø 7.25mm
Screen : bare copper wire braid 
Outer jacket : black LSZH material
Marking : APS Finland – ww/yy – RG 213 type MIL LSZH – 50 OHM – P/N – lot + meter

Armoured version is supplied with additional:
Armour : galvanized steel or tinned copper wire braid
Outer jacket : black LSZH material
Marking : APS Finland – ww/yy – ARMOURED RG 213 type MIL LSZH – 50 OHM – P/N – lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 
Halogen acid gas corrosiveness : TS EN 50267-2-3
Smoke Emission : IEC 61034-2
Flame retardant : IEC 60332-1-1, IEC60332-2-1

Electrical characteristics

Impedance : 50 ± 3 ᘯ 
Capacitance : 101pF/m nominal
Velocity ratio : 66%
Insulation resistance :  10000 MΩ x Km

Spark tension of the sheath : 2.0 kV

 

Attenuation (typical)

MHz100200400600800100015002000300052005800
dB7.211.015.521.025.029.033.037.547.663.268.5

 

Ordering and delivery information

TypeP/NO.D [mm]Weight [kg/km]Packaging
RG213 Non-armouredRG213MT10.2163500m or 1000m (+/-5%)
RG213 armoured GSWB RG213MTBH14.5250500m (+/-5%)
RG213 armoured TCWB RG213MTTH14.5235500m (+/-5%)

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.