Offshore universal armoured cable UT92U 2-24 cores, MUD-Resistant, 1500N

   
*All images are indicative

Installation features

Store at : -40 to +70°C
Install at : -5 to +50°CBend minimum : 20 times O.D.
Operate at : -40 to +85°CBend minimum : 15 times O.D.

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.8mm up to 12 fibers, Ø3.5mm for 16-24 fibers) filled with jelly, housing up to 24 fibers
Protection :  anti-rodent glass yarns, water blocking.
Armour:  corrugated steel tape.
Outer sheath : black fire retardant, UV-resistant and MUD-resistant LSZH SHF2 material (nom. thick. ≥1.0mm).
Marking :  APS Finland ww/mm – FIBER OPTIC CABLE UT92U [fibre count and type] – SHF2-MUD NEK606 – IEC 60332-3-24 – Lot no + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
Weather resistant : ASTM G 154, EN 11507
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : ASTM G 154 IEC 60068-2-5

 

Mechanical properties

Pulling tension :  1500 N (Δα reversible, IEC 60794-1-2-E1)
Crush :  1000N/100mm (Δα reversible, IEC 60794-1-2-E3)
Impact :  5J (Δα reversible, IEC 60794-1-2-E4)
Water penetration :  3m cable, 1m water, 24 hours (IEC 60794-1-2-F5)

 

Colour code of fibers

123456789101112
BlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAqua
131415161718192021222324
Blue/b.Orange/b.Green/b.Brown/b.Grey/b.White/b.Red/b.NaturalYellow/b.Violet/b.Pink/b.Aqua/b.

 

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber CountPart NumberNo. of tubesFibers per tubeNominal O.D. (mm)Weight (kg/km)Packaging
2UT92U02 ff D2129.5120Drum 2000m +/-5%
4UT92U04 ff D2149.5120Drum 2000m +/-5%
8UT92U08 ff D2189.5120Drum 2000m +/-5%
12UT92U12 ff D21129.5120Drum 2000m +/-5%
24UT92U24 ff D21249.5120Drum 2000m +/-5%

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

 

 

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



Offshore universal fire resistant, armoured fibre optic cable UTX92U 2-24 cores, MUD-Resistant, 1500N

   
*All images are indicative

Installation features

Store at : -40 to +70°C
Install at : -5 to +50°CBend minimum : 20 times O.D.
Operate at : -40 to +85°CBend minimum : 15 times O.D.

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.8mm up to 12 fibers, Ø3.5mm for 16-24 fibers) filled with jelly, housing up to 24 fibers
Fire barrier :  mica tape.
Protection :  anti-rodent glass yarns, water blocking.

Armour:  corrugated steel tape.
Outer sheath : black fire retardant, UV-resistant and MUD-resistant LSZH SHF2 material (nom. thick. ≥1.0mm).
Marking :  APS Finland ww/mm – FIBER OPTIC CABLE UTX92U [fibre count and type] – SHF2-MUD NEK606 – IEC60331-25 IEC60332-3-24 – Lot no + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Fire resistant : IEC 60331-25 (90 min.)
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
Weather resistant : ASTM G 154, EN 11507
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : ASTM G 154 IEC 60068-2-5

 

Mechanical properties

Pulling tension :  1500 N (Δα reversible, IEC 60794-1-2-E1)
Crush :  1000N/100mm (Δα reversible, IEC 60794-1-2-E3)
Impact :  5J (Δα reversible, IEC 60794-1-2-E4)
Water penetration :  3m cable, 1m water, 24 hours (IEC 60794-1-2-F5)

 

Colour code of fibers

123456789101112
BlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAqua
131415161718192021222324
Blue/b.Orange/b.Green/b.Brown/b.Grey/b.White/b.Red/b.NaturalYellow/b.Violet/b.Pink/b.Aqua/b.

 

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber CountPart NumberNo. of tubesFibers per tubeNominal O.D. (mm)Weight (kg/km)Packaging
2UTX92U02 ff D2129.5120Drum 2000m +/-5%
4UTX92U04 ff D2149.5120Drum 2000m +/-5%
8UTX92U08 ff D2189.5120Drum 2000m +/-5%
12UTX92U12 ff D21129.5120Drum 2000m +/-5%
24UTX92U24 ff D21249.5120Drum 2000m +/-5%

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

 

 

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



LIACC FO Access cable MTAH 2-72 cores, IN/OUT, SWA Armoured

  
*All images are indicative
Features

Outdoor, indoor and duct installation
Metallic armour
Low Smoke Zero Halogen

 

Standards of reference and applications

IEC 60793, IEC 60794
Telecommunication backabones
Intrabuilding Voice and Data/LAN Communication Networks

Installation in Ducts & Conduits 

 

Installation Features

Store at  -40 to +70 °C
Install at -10 to +60 °C, Bend minimum 20 times O.D. (installation)
Operate at  -40 to +70 °CBend minimum 15 times O.D. (static)

 

Design

Bare fiber : 250µm, SM or MM
Colour code : See table
Buffer : Loose tube (nom 1.9mm) filled with jelly, housing up to 12 fibers.
Colour code : See table
Central member : Thermoplastic resin coated single strand (FRP)
Cable core : Loose tubes and fillers (when necessary) assembled around the central member.
Wrapping :  water blocking tape.
Inner sheath : Black LSZH material.
Armour : single layer of galvanized steel wires. Coverage ≥80%.
Outer jacket : Black LSZH UV-Resistant material. Nominal outer diameter 14.5mm.
Marking : APS Finland ww/mm – Fiber Optic Cable MTAH “fiber count and type” – LSZH IEC60332-3-24 Cat.C – lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 
Halogen acid gas : IEC 60754-1, IEC 60754-2
Smoke Emission : IEC 61034-2, EN 50268-2
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Mechanical properties

Pulling tension :  max 3000 N (Δα reversible, IEC 60794-1-2-E1)
Crush :  3000N/100mm (Δα reversible, IEC 60794-1-2-E3)
Impact :  30J (Δα reversible, IEC 60794-1-2-E4)
Water penetration :  3m cable, 1m water, 24 hours (IEC 60794-1-2-F5), inner core only

 

Colour code

 123456789101112
Tube ColoursRedGreenNaturalNaturalNaturalNatural
FillersBlack
Fiber ColoursBlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAqua

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber CountPart NumberNo. of tubesFibers per tubeFillersO.D. (mm)Weight (kg/km)Packaging
2MTAH3002 xx12514.5280Drum 2000m +/-5%
4MTAH3004 xx14514.5280Drum 2000m +/-5%
8MTAH3008 xx18514.5280Drum 2000m +/-5%
12MTAH3012 xx112514.5280Drum 2000m +/-5%
24MTAH3024 xx212414.5280Drum 2000m +/-5%
48MTAH3048 xx412214.5280Drum 2000m +/-5%
72MTAH3072 xx612014.5280Drum 2000m +/-5%

xx = fiber type                  OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4, OM5=M5
(*) a tolerance of ±5% applies to the delivery length.               

 

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



LIACC FO Access cable UTAH 2-24 cores, SWA Armoured, Fire Retardant & LSZH

  
*All images are indicative

Features

Outdoor, duct and direct burial installation
Metallic armour
Excellent rodent resistance
Watertight
Fire Retardant, LSZH

 

 

Standards of reference and applications

IEC 60793, IEC 60794
Telecommunication backabones
Intrabuilding Voice and Data/LAN Communication Networks

Installation in Ducts & Conduits or Directly Buried
Building access in FTTx networks

 

Installation Features

Store at  -40 to +70 °C
Install at -10 to +60 °C, Bend minimum 20 times O.D. (installation)
Operate at  -40 to +70 °CBend minimum 15 times O.D. (static)

 

Design

Optical fiber : 125/250μm Single Mode or Multi Mode
Buffer : PBTP loose tube filled with jelly, nominal diameter 3.5mm (2-12 cores), 4.5mm (16, 24 cores).
Inner strength member :  aramide yarns.
Inner jacket :  LSZH black, nominal thickness 1.0mm.

Armour:  steel wire, one layer, coverage ≥80%.
Outer jacket : LSZH black, UV resistant, nominal thickness 1.5mm.
Marking : APS Finland – ww/yy – Armoured Fiber Optic Cable UTAH fiber count x fiber type – P/N – lot + meter

 

Environmental properties

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 
Halogen acid gas : IEC 60754-1, IEC 60754-2 
Smoke Emission : IEC 61034-2, EN 50268-2
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Oil resistant : intermittent splash – permanent resistance available upon request
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : ASTM G 154 IEC 60068-2-5

 

Mechanical properties

Impact :  5J (Δα reversible, IEC 60794-1-2-E4)
Repeated bending :  25 cycles (IEC 60794-1-21 E6, r = 220mm, 4Kg)

Torsion :  10 Turns (IEC 60794-1-21 E7, 2m, ±180°, 4Kg)
Water penetration :  3m cable, 1m water, 24 hours (IEC 60794-1-2-F5)

 

Colour code of fibers

123456789101112
BlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAqua
131415161718192021222324
Blue/b.Orange/b.Green/b.Brown/b.Grey/b.White/b.Red/b.NaturalYellow/b.Violet/b.Pink/b.Aqua/b.

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber CountPart NumberNo. of tubesFibers per tubeNominal O.D. (mm)Weight (kg/km)Pulling tension (installation)Pulling tension (operation)Packaging (*)
2UTAH02xxoo1211.12174500N3500NDrum
4UTAH04xxoo1411.12174500N3500NDrum
8UTAH08xxoo1811.12174500N3500NDrum
12UTAH12xxoo11211.12174500N3500NDrum
16UTAH16xxoo11612.32406000N4500NDrum
24UTAH24xxoo12412.32406000N4500NDrum

xx = fiber type                  OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4, OM5=M5
oo = delivery length         2000m=D2
(*) a tolerance of ±5% applies to the delivery length.               

 

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



MOG Fiber Optic Cable CT25H9H 2-24 cores, CST Armoured, Fire Retardant & LSZH

  
*All images are indicative

Features

  • Outdoor and duct installation
  • Metallic armour
  • Excellent rodent resistance
  • Watertight
  • Fire Retardant, LSZH, UV-Resistant

 

 

Standards of reference and applications

  • IEC 60793, IEC 60794
  • Telecommunication backbones
  • Intrabuilding Voice and Data/LAN Communication Networks
  • Installation in Ducts & Conduits or open air
  • Building access in FTTx networks
  • Marine, Oil&Gas, Onshore & Offshore 
  • Heavy duty 

 

Installation Features

Store at  -10 to +70 °C
Install at -0 to +50 °C, Bend minimum 20 times O.D. (installation)
Operate at  -30 to +70 °CBend minimum 10 times O.D. (static)

 

Design

Optical fiber : 125/250μm Single Mode or Multi Mode
Buffer : PBTP loose tube filled with jelly, nominal diameter 2.8-3.5mm (2-12 cores) or 4.2-4.5mm (16, 24 cores).
Inner strength member :  glass yarns.
Inner jacket :  LSZH black, nominal thickness 1.0mm.

Armour:  corrugated steel tape, optical coverage 100%.
Outer jacket : LSZH black, UV resistant, nominal thickness 1.5mm.
Marking : APS Finland – ww/yy – Armoured Fiber Optic Cable CT25H9H fiber count x fiber type – P/N – lot + meter

 

Environmental properties

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 
Halogen acid gas : IEC 60754-1, IEC 60754-2 
Smoke Emission : IEC 61034-2, EN 50268-2
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : ASTM G 154, IEC 60068-2-5, UL1581

 

Mechanical properties

Pulling tension : 2500N (installation), 1000N (operation);
Crush :  2500N/100mm;

Impact :
  5J 
Repeated bending :  25 cycles
Torsion :  10 Turns
Water penetration :  3m cable, 1m water, 24 hours (IEC 60794-1-2-F5)

 

Colour code of fibers

123456789101112
Bundle ABlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAqua
131415161718192021222324
Bundle BBlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAqua

 

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber CountPart NumberNo. of tubesFibers per tubeNominal O.D. (mm)Weight (kg/km)Packaging (*)
2CT25H9H02xxoo1211.5185Drum
4CT25H9H04xxoo1411.5185Drum
8CT25H9H08xxoo1811.5185Drum
12CT25H9H12xxoo11211.5185Drum
16CT25H9H16xxoo11613.0220Drum
24CT25H9H24xxoo12413.0220Drum

xx = fiber type                  OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4, OM5=M5
oo = delivery length         2000m=D2, 4000m=D4
(*) a tolerance of ±5% applies to the delivery length.               

 

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



MTA1 Fire Resistant Double Armoured SHF1

   

 

 

 

Store at : -30 to +70 °C
Install at : – 5 to +50 °C, Bend minimum : 25 times O.D.
Operate at : -40 to +70 °C, Bend minimum : 20 times O.D.
Pull maximum : 8000N
Crush maximum : 3000N/100mm
Impact maximum : 10J
Cable nominal weight : 590 kg/km
Cable elong. : 0.5%
Fibre elong. : 0.33%
Breaking load: 12 000 N

 

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø1.9mm) filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : Thermoplastic resin coated single strand
Cable core : Loose tubes and fillers (when necessary) assembled around the central member. The core is wrapped by a synthetic tape.
Inner sheath : Black LSZH material 1.0mm thick. Nominal diameter 9.0mm.
Armour : Double layer of galvanized steel wires. Coverage ≥80%.
Outer jacket : Black LSZH SHF1 material 1.5mm thick. Nominal outer diameter 15.7mm.
Marking : APS Finland ww/mm – Fiber Optic Cable MTA1 “fiber count and type” – SHF1 IEC60331-25 IEC60332-3-22 Cat A – lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25
Oil resistant : intermittent splash – permanent resistance available upon request
Water absorption : IEC60502
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Colour code of fibers

  01. 02. 03. 04. 05. 06. 07. 08. 09. 10. 11. 12. 
Natural Red Green Yellow Brown Blue Violet Orange Grey White Black Pink 

 

 

Colour code of tubes

  Tube 4-12 fibers 24 fibers 36 fibers 48 fibers 72 fibers 
Red (4-12 fibers) Red (12 fibers) Red (12 fibers) Red (12 fibers) Red (12 fibers) 
Filler Green (12 fibers) Green (12 fibers) Green (12 fibers) Green (12 fibers) 
Filler Filler Natural (12 fibers) Natural (12 fibers) Natural (12 fibers) 
Filler Filler Filler Natural (12 fibers) Natural (12 fibers) 
Filler Filler Filler Filler Natural (12 fibers) 
Filler Filler Filler Filler Natural (12 fibers) 

Ordering and delivery information

  Fiber count SM OM1 OM1+ OM2 OM3 OM4 Packaging 
MTA104S2 MTA104M1 MTA104ME MTA104M2 MTA104M3 MTA104M4 drum 2000m (+/-5%) 
MTA108S2 MTA108M1 MTA108ME MTA108M2 MTA108M3 MTA108M4 drum 2000m (+/-5%) 
12 MTA112S2 MTA112M1 MTA112ME MTA112M2 MTA112M3 MTA112M4 drum 2000m (+/-5%) 
24 MTA124S2 MTA124M1 MTA124ME MTA124M2 MTA124M3 MTA124M4 drum 2000m (+/-5%) 
36 MTA136S2 MTA136M1 MTA136ME MTA136M2 MTA136M3 MTA136M4 drum 2000m (+/-5%) 
48 MTA148S2 MTA148M1 MTA148ME MTA148M2 MTA148M3 MTA148M4 drum 2000m (+/-5%) 
72 MTA172S2 MTA172M1 MTA172ME MTA172M2 MTA172M3 MTA172M4 drum 2000m (+/-5%) 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1Type Approval Program - Optical Fibre Cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables

 

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 

 

 

 

 




MTFH Fire Resistant Single SWA Armoured LSZH

   

 

Features

Suitable for duct and underground installation
Rodent protected
Dry core
Waterproof
Fire resistant
Flame retardant
Halogen free and Low smoke emission
UV stabilized

 

Storage and handling 

Store at : -40 to +80 °C
Install at : -10 to +60 °C, Bend minimum : 20 times O.D.
Operate at : -40 to +80 °C, Bend minimum : 10 times O.D.
Pull maximum : 2500N (installation), 800N (permanent)
Crush maximum : 3500N/100mm
Impact maximum : 10J
Cable nominal weight : 370 kg/km

 

Design

Bare fiber : 250µm
Colour code : See table
Buffer : Loose tube filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : Thermoplastic resin coated single strand
Cable core : Loose tubes and fillers (when necessary) assembled around the central member.
Peripheral strength member : swellable glass yarns.
Wrapping :  water blocking tape.
Inner sheath : Black LSZH material.
Armour : single layer of galvanized steel wires. Coverage ≥80%.
Outer jacket : Black LSZH UV-Resistant material. Nominal outer diameter 14.5mm.
Marking : APS Finland ww/mm – Fiber Optic Cable MTFH “fiber count and type” – LSZH IEC60331-25 IEC60332-3-24 Cat.C – lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 
Halogen acid gas : IEC 60754-1, IEC 60754-2
Smoke Emission : IEC 61034-2, EN 50268-2
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Fire resistant : IEC 60331-25
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Colour code of fibers

  01. 02. 03. 04. 05. 06. 07. 08. 09. 10. 11. 12. 
Natural Red Green Yellow Brown Blue Violet Orange Grey White Black Pink 

Other colour code available upon request.

 

Colour code of tubes

  Tube 4-12 fibers 24 fibers 36 fibers 48 fibers 
Red (4-12 fibers) Red (12 fibers) Red (12 fibers) Red (12 fibers) 
Filler Green (12 fibers) Green (12 fibers) Green (12 fibers) 
Filler Filler Natural (12 fibers) Natural (12 fibers) 
Filler Filler Filler Natural (12 fibers) 

Other colour code available upon request.

Ordering and delivery information

  Fiber count P/NPackaging 
MTFH04xx drum 2000m (+/-5%) 
MTFH08xxdrum 2000m (+/-5%) 
12 MTFH12xxdrum 2000m (+/-5%) 
24 MTFH24xxdrum 2000m (+/-5%) 
36 MTFH36xxdrum 2000m (+/-5%) 
48 MTFH48xxdrum 2000m (+/-5%) 

xx = fiber type : OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4, OM5=M5

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1Type Approval Program - Optical Fibre Cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables

 

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 

 

 

 

 




MTB1 Fire Resistant Double Braided SHF1

   

 

 

 

Store at : -30 to +70 °C
Install at : – 5 to +50 °CBend minimum : 25 times O.D.
Operate at : -40 to +70 °CBend minimum : 20 times O.D.
Pull maximum : 3000N
Crush maximum : 1500N/100mm
Impact maximum : 10J
Cable nominal weight : 350 kg/km

 

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø1.9mm) filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : Thermoplastic resin coated single strand
Cable core : Loose tubes and fillers (when necessary) assembled around the central member. The core is wrapped by a synthetic tape.
Inner sheath : Black LSZH material 1.0mm thick. Nominal diameter 9.0mm.
Armour : Double layer of galvanized steel, tinned copper or bronze wires separated by a synthetic tape. Coverage ≥80%.
Outer jacket : Black LSZH SHF1 material 1.5mm thick. Nominal outer diameter 14.5mm.
Marking : APS Finland ww/mm – Fiber Optic Cable MTB1 “fiber count and type” – SHF1 IEC60331-25 IEC60332-3-22 Cat A – lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25
Oil resistant : intermittent splash – permanent resistance available upon request
Water absorption : IEC60502
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

 

Colour code of fibers

  01. 02. 03. 04. 05. 06. 07. 08. 09. 10. 11. 12. 
Natural Red Green Yellow Brown Blue Violet Orange Grey White Black Pink 

 

 

Colour code of tubes

  Tube 4-12 fibers 24 fibers 36 fibers 48 fibers 72 fibers 
Red (4-12 fibers) Red (12 fibers) Red (12 fibers) Red (12 fibers) Red (12 fibers) 
Filler Green (12 fibers) Green (12 fibers) Green (12 fibers) Green (12 fibers) 
Filler Filler Natural (12 fibers) Natural (12 fibers) Natural (12 fibers) 
Filler Filler Filler Natural (12 fibers) Natural (12 fibers) 
Filler Filler Filler Filler Natural (12 fibers) 
Filler Filler Filler Filler Natural (12 fibers) 

 

Ordering and delivery information

  Fiber count SM OM1 OM1+ OM2 OM3 OM4 Packaging 
MTB104S2 MTB104M1 MTB104ME MTB104M2 MTB104M3 MTB104M4 drum 2000m (+/-5%) 
MTB108S2 MTB108M1 MTB108ME MTB108M2 MTB108M3 MTB108M4 drum 2000m (+/-5%) 
12 MTB112S2 MTB112M1 MTB112ME MTB112M2 MTB112M3 MTB112M4 drum 2000m (+/-5%) 
24 MTB124S2 MTB124M1 MTB124ME MTB124M2 MTB124M3 MTB124M4 drum 2000m (+/-5%) 
36 MTB136S2 MTB136M1 MTB136ME MTB136M2 MTB136M3 MTB136M4 drum 2000m (+/-5%) 
48 MTB148S2 MTB148M1 MTB148ME MTB148M2 MTB148M3 MTB148M4 drum 2000m (+/-5%) 
72 MTB172S2 MTB172M1 MTB172ME MTB172M2 MTB172M3 MTB172M4 drum 2000m (+/-5%) 

For an armour different than Galvanized Steel add “B” for bronze braid or “T” for tinned copper braid at the end of the P/N.

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1Type Approval Program - Optical Fibre Cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 




QFCB / QFOB Armoured MUD NEK606 Fire Resistant IEC60331-25, Fire Retardant IEC60332-3-22 Cat.A

 

    

 

Store at : -40 to +70 °C
Install at : -10 to +50 °C, Bend minimum : 20 times O.D.
Operate at : -40 to +70 °C, Bend minimum : 15 times O.D.
Pull maximum : 2000N
Crush maximum : 3000N/100mm
Impact maximum : 20J
Cable weight : 260 kg/km

 

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.2mm) filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : Steel rope with LSZH sheath
Cable core : Loose tubes and fillers (when necessary) are stranded around the central member. The core is wrapped by a tape.
Inner sheath : Black SHF1 material 1.0mm thick. Nominal outer diameter 10.1mm.
Armour : Galvanized steel, bronze or tinned copper wire braid. Coverage ≥85%.
Outer jacket : Black LSZH Fire Retardant material, MUD Resistant 1.5mm thick. Nominal outer diameter 13.5mm.
Marking : APS Finland ww/yy – Fiber Optic Cable QF_B “fiber count and type” – SHF2 MUD RESISTANT NEK606 IEC60332-3-22 Cat A – lot + m

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
Weather resistant : ASTM G 154, EN 11507
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact : CSA C22.2

 

 

 

Ordering and delivery information

Fiber countSMOM1OM1+OM2OM3OM4Packaging
2OQFCI02S2UOQFCI02M1UOQFCI02MEUOQFCI02M2UOQFCI02M3UOQFCI02M4Udrum 2000m (+/-5%)
4OQFCI04S2UOQFCI04M1UOQFCI04MEUOQFCI04M2UOQFCI04M3UOQFCI04M4Udrum 2000m (+/-5%)
6OQFCI06S2UOQFCI06M1UOQFCI06MEUOQFCI06M2UOQFCI06M3UOQFCI06M4Udrum 2000m (+/-5%)
8OQFCI08S2UOQFCI08M1UOQFCI08MEUOQFCI08M2UOQFCI08M3UOQFCI08M4Udrum 2000m (+/-5%)
12OQFCI12S2UOQFCI12M1UOQFCI12MEUOQFCI12M2UOQFCI12M3UOQFCI12M4Udrum 2000m (+/-5%)
24OQFCI24S2UOQFCI24M1UOQFCI24MEUOQFCI24M2UOQFCI24M3UOQFCI24M4Udrum 2000m (+/-5%)
48OQFCI48S2UOQFCI48M1UOQFCI48MEUOQFCI48M2UOQFCI48M3UOQFCI48M4Udrum 2000m (+/-5%)

Note : for tinned copper braid add “T” at the end of the P/N, for bronze braid add “B” at the end of the P/N.

 

Colour code of fibers 

123456789101112
BlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAqua

 

Colour code of tubes

123456789101112Fillers
BlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAquaBlack

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1Type Approval Program - Optical Fibre Cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



Fiber Optic cable CTG1N215, single loose tube, armoured, LSZH SHF2, fire retardant

 

      

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -40 to +90 °CBend minimum : 20 times O.D.
Pull maximum : 1500N
Crush maximum : 2000N/100mm
Impact maximum : 5J
Cable weight : 268 kg/km

 

 

Design

Bare fiber : 250µm
Buffer : Loose tube (typical Ø3.0mm) filled with jelly, housing up to 24 fibers
Colour code : See table
Peripheral members : anti-rodent glass yarns
Inner sheath : Black LSZH SHF1 material, fire retardant.
Armour : double layer of helically applied steel tape, with overlap. Optical coverage100%.
Outer jacket : Black LSZH cross-linked  material SHF2, UVR, fire retardant (nominal thickness 1.8mm).
Marking : APS Finland – ww/mm – Fiber Optic Cable CTG1N215 “fiber count and type” – LSZH  SHF2  IEC60332-3-22 Cat.A – lot + meter

Environmental properties and fire performances

SHF2 : IEC 60092-360 (IEC 60092-359:1987-03)
Degree of acidity of gases :
IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)

Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas :  NES 713, CEI 20-37/7
Flame retardant :  IEC 60332-1-2
Fire retardant :  IEC 60332-3-22 Cat.A
Ozone resistant : DIN VDE 0472 part 805 B
Oil resistant :  IEC60811
Water absorption : IEC60502
Water penetration : IEC 60794-1-2-F5-B
UV resistant : ASTM G 154 IEC 60068-2-5

 

Ordering and delivery information

Fiber countP/NPackaging
2CTG1N21502 ffdrum 2000m (+/-5%)
4CTG1N21504 ffdrum 2000m (+/-5%)
8CTG1N21508 ffdrum 2000m (+/-5%)
12CTG1N21512 ffdrum 2000m (+/-5%)
16CTG1N21516 ffdrum 2000m (+/-5%)
24CTG1N21524 ffdrum 2000m (+/-5%)

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

 

 

Colour code of fibers

123456789101112
BlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAqua
131415161718192021222324
Blue/b.Orange/b.Green/b.Brown/b.Grey/b.White/b.Red/b.NaturalYellow/b.Violet/b.Pink/b.Aqua/b.

 

Colour code of tubes

Natural

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



Fiber Optic cable FRSCTAU, loose tube, armoured SWA, MUD, fire resistant, fire retardant IEC60332-3-22 Cat.A

 

      

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -40 to +70 °CBend minimum : 20 times O.D.
Pull maximum : 3000N
Crush maximum : 2000N/100mm
Impact maximum : 10J
Cable weight : 268 kg/km

 

 

Design

Bare fiber : 250µm
Buffer : Loose tube (typical Ø3.0mm) filled with jelly, housing up to 24 fibers
Colour code : See table
Fire protection : A fire barrier is applied over the tube
Peripheral members : anti-rodent, water blocking glass yarns
Inner sheath : Black LSZH material, fire retardant.
Armour : concentrically applied steel wire armour. Coverage ≥80%.
Outer jacket : Black LSZH material, fire retardant, MUD and oil resistant. Nominal outer diameter 14.0mm.
Marking : APS Finland ww/mm – Fiber Optic Cable FRSCTAU “fiber count and type” – LSZH MUD IEC60332-3-22 Cat.A  IEC60331-25 – lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
Weather resistant : ASTM G 154, EN 11507
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact : CSA C22.2 (-40°C)
Onshore : SEIC Cable Specification 1000-S-40-68-S-3014-00 Rev 06 sections 5.2.2.2 and 5.7

Ordering and delivery information

Fiber countP/NPackaging
2FRSCTAU02 ffdrum 2000m (+/-5%)
4FRSCTAU04 ffdrum 2000m (+/-5%)
8FRSCTAU08 ffdrum 2000m (+/-5%)
12FRSCTAU12 ffdrum 2000m (+/-5%)
16FRSCTAU16 ffdrum 2000m (+/-5%)
24FRSCTAU24 ffdrum 2000m (+/-5%)

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

 

 

Colour code of fibers

123456789101112
BlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAqua
131415161718192021222324
Blue/b.Orange/b.Green/b.Brown/b.Grey/b.White/b.Red/b.NaturalYellow/b.Violet/b.Pink/b.Aqua/b.

 

Colour code of tubes

Natural

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



Fiber Optic cable FRSMTAHA , loose tube, armoured SWA, LSZH-ATAR, fire resistant, fire retardant

 

      

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -40 to +70 °CBend minimum : 20 times O.D.
Pull maximum : 3000N
Crush maximum : 3000N/100mm
Impact maximum : 10J
Cable weight : 368 kg/km

 

 

Design

Bare fiber : 250µm
Buffer : Loose tube filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : FRP
Cable core : Loose tubes and fillers (when necessary) are stranded around the central member. 
Inner sheath : Black LSZH material, fire retardant.
Armour : steel wire armour. Coverage ≥80%.
Outer jacket : Black LSZH material, fire retardant, anti-termite & anti-rodent.  
Marking : APS Finland ww/mm – Fiber Optic Cable FRSMTAHA “fiber count and type” – LSZH ATAR IEC60332-3-24 Cat.C  IEC60331-25 – lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Fire resistant : IEC 60331-25 
Water penetration : IEC 60794-1-2-F5-B (tubes only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Ordering and delivery information

Fiber countP/NOverall diameter (nom.)Packaging
2FRSMTAHA02 ff15.2 mmdrum 2000m (+/-5%)
4FRSMTAHA04 ff15.2 mmdrum 2000m (+/-5%)
8FRSMTAHA08 ff15.2 mmdrum 2000m (+/-5%)
12FRSMTAHA12 ff15.2 mmdrum 2000m (+/-5%)
24FRSMTAHA24 ff15.2 mmdrum 2000m (+/-5%)
48FRSMTAHA48 ff15.2 mmdrum 2000m (+/-5%)
72FRSMTAHA72 ff15.2 mmdrum 2000m (+/-5%)

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

 

 

Colour code of fibers

123456789101112
BlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAqua

 

Colour code of tubes

123456789101112Fillers
BlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAquaBlack

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1Type Approval Program - Optical Fibre Cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



Fiber Optic cable FRSMTAHR , loose tube, armoured SWA, LSZH, fire resistant, fire retardant IEC60332-3-22 Cat.A

 

      

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -40 to +70 °CBend minimum : 20 times O.D.
Pull maximum : 3000N
Crush maximum : 3000N/100mm
Impact maximum : 20J
Cable weight : 368 kg/km

 

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.1mm) filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : FRP
Cable core : Loose tubes and fillers (when necessary) are stranded around the central member. 
Inner sheath : Black LSZH material, fire retardant.
Armour : steel wire armour. Coverage ≥80%.
Outer jacket : Black LSZH material, fire retardant, oil resistant. Nominal outer diameter 15.2mm.
Marking : APS Finland ww/mm – Fiber Optic Cable FRSMTAHR “fiber count and type” – LSZH IEC60332-3-22 Cat.A  IEC60331-25 – lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25 
Water penetration : IEC 60794-1-2-F5-B (tubes only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Ordering and delivery information

Fiber countP/NPackaging
2FRSMTAHR02 ffdrum 2000m (+/-5%)
4FRSMTAHR04 ffdrum 2000m (+/-5%)
8FRSMTAHR08 ffdrum 2000m (+/-5%)
12FRSMTAHR12 ffdrum 2000m (+/-5%)
24FRSMTAHR24 ffdrum 2000m (+/-5%)
48FRSMTAHR48 ffdrum 2000m (+/-5%)

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

 

 

Colour code of fibers

123456789101112
BlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAqua

 

Colour code of tubes

123456789101112Fillers
BlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAquaBlack

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



Fiber Optic cable FRSMTAU , loose tube, armoured SWA, MUD, fire resistant, fire retardant IEC60332-3-22 Cat.A

 

      

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -40 to +70 °CBend minimum : 20 times O.D.
Pull maximum : 3000N
Crush maximum : 3000N/100mm
Impact maximum : 20J
Cable weight : 368 kg/km

 

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.1mm) filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : FRP
Cable core : Loose tubes and fillers (when necessary) are stranded around the central member. 
Inner sheath : Black LSZH material, fire retardant.
Armour : steel wire armour. Coverage ≥80%.
Outer jacket : Black LSZH material, fire retardant, MUD and oil resistant. Nominal outer diameter 16.0mm.
Marking : APS Finland ww/mm – Fiber Optic Cable FRSMTAU “fiber count and type” – LSZH MUD IEC60332-3-22 Cat.A  IEC60331-25 – lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
Weather resistant : ASTM G 154, EN 11507
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact : CSA C22.2 (-40°C)
Onshore : SEIC Cable Specification 1000-S-40-68-S-3014-00 Rev 06 sections 5.2.2.2 and 5.7

Ordering and delivery information

Fiber countP/NPackaging
2FRSMTAU02 ffdrum 2000m (+/-5%)
4FRSMTAU04 ffdrum 2000m (+/-5%)
8FRSMTAU08 ffdrum 2000m (+/-5%)
12FRSMTAU12 ffdrum 2000m (+/-5%)
24FRSMTAU24 ffdrum 2000m (+/-5%)
48FRSMTAU48 ffdrum 2000m (+/-5%)

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

 

 

Colour code of fibers

123456789101112
BlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAqua

 

Colour code of tubes

123456789101112Fillers
BlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAquaBlack

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



Fiber optic cable, loose tube, dielectric, LSZH, fire resistant & fire retardant

 

     

 

Store at : -40 to +70 °C
Install at : 0 to +50 °CBend minimum : 15 times O.D.
Operate at : -40 to +70 °CBend minimum : 10 times O.D.
Pull maximum : 2000N
Crush maximum : 2500N/100mm
Impact maximum : 3J

 

Design

Bare fiber : 250µm
Buffer : Loose tube
Colour code : See table
Fire protection :  mica tape wrapping
Dielectric armour :  anti rodent glass yarns
Outer sheath : red fire retardant LSZH material, typical thickness 1.0mm
Marking :  APS Finland ww/mm – FIRECA – FIBER OPTIC CABLE [Fibre count and type] – LSZH  IEC 60331-25  IEC 60332-3-24 – Lot no + meter 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 
Halogen acid gas : IEC 60754-1, IEC 60754-2  
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Fire resistant : IEC 60331-25 (90 min @ 750°C)
Water absorption : IEC 60502
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : ASTM G 154 IEC 60068-2-5, EN50289-4-17:2015

 

Ordering and delivery information

Fiber countOuter diameter (mm, nominal)Weight (kg/km)P/NPackaging
28.070UTXH2002 ffdrum 2000m (+/-5%)
48.070UTXH2004 ff drum 2000m (+/-5%)
88.070UTXH2008 ff drum 2000m (+/-5%)
128.070UTXH2012 ff drum 2000m (+/-5%)
168.575UTXH2016 ff drum 2000m (+/-5%)
248.575UTXH2024 ff drum 2000m (+/-5%)

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

 

 

Colour code of fibers

123456789101112
Bundle ABlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAqua
131415161718192021222324
Bundle BBlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAqua

 

 

Other standards of reference

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



FRSCTAH type, loose tube, SWA armoured, LSZH, fire resistant, fire retardant

 

   

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -40 to +70 °CBend minimum : 15 times O.D.
Pull maximum : 4000N
Crush maximum : 4000N/100mm
Impact maximum : 30J

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.8mm up to 12 fibers, Ø3.5mm 16-24) filled with jelly, housing up to 24 fibers
Colour code : See table
Fire protection :  mica tape wrapping.
Protection :  anti rodent glass yarns.
Inner sheath : red fire retardant LSZH material, typical thickness 1.0mm.
Armour : galvanised steel wires, helically applied. Min coverage 80%. 

Outer sheath : red fire retardant UVR LSZH material, typical thickness 1.0mm.
Marking :  APS Finland ww/mm – FRSCTAH UNI – FIBER OPTIC CABLE [Fibre type] – IEC 60331-25 – IEC 60332-3-24 – Lot no + meter 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Fire resistant : IEC 60331-25 
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Ordering and delivery information

Fiber countOuter diameter (mm)Weight (kg/km)Part NumberPackaging
211.0220FRSCTAH 02 ffdrum 2000m (+/-5%)
411.0220FRSCTAH 04 ffdrum 2000m (+/-5%)
811.0220FRSCTAH 08 ffdrum 2000m (+/-5%)
1211.0220FRSCTAH 12 ffdrum 2000m (+/-5%)
2412.0220FRSCTAH 24 ffdrum 2000m (+/-5%)

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

 

 

 

 

Colour code of fibers

010203040506070809101112
WhiteRedYellowGreenBlueGreyBrownBlackVioletTurquoiseOrangePink

 

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1Type Approval Program - Optical Fibre Cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



QFAI 2 UNI MUD type (QFAB-2), loose tube, dielectric, SHF2-MUD, fire resistant IEC60331, fire retardant IEC60332-3-22 Cat.A

 

    

 

Store at : -40 to +70 °C
Install at : -5 to +50 °CBend minimum : 15 times O.D.
Operate at : -40 to +70 °CBend minimum : 10 times O.D.
Pull maximum : 3500N
Crush maximum : 4000N/100mm
Impact maximum : 20J

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.8mm up to 12 fibers, Ø3.5mm 16-24) filled with jelly, housing up to 24 fibers
Colour code : See table
Fire protection :  mica tape wrapping.
Peripheral member :  anti rodent glass yarns.
Inner sheath : red fire retardant LSZH SHF1 material, typical thickness 1.0mm.
Dielectric armour :  anti rodent glass yarns.
Outer sheath : red fire retardant, UV-resistant and MUD-resistant LSZH SHF2 material, typical thickness 1.0mm.

Marking :  APS Finland ww/mm – QFAI 2 UNI SHF2-MUD (QFAB-2) – FIBER OPTIC CABLE [Fibre type] – IEC 60331-25 [1000°C 90min] – IEC 60332-3-22 – Lot no + meter [A]

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25 (1000°C, 90 minutes)
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
Weather resistant : ASTM G 154, EN 11507
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : ASTM G 154 IEC 60068-2-5
Cold bend & impact : CSA C22.2

 

Ordering and delivery information

Fiber countOuter diameter (mm)Weight (kg/km)P/NPackaging
210.5160OQFAB202 ff drum 2000m (+/-5%)
410.5160OQFAB204 ff drum 2000m (+/-5%)
810.5160OQFAB208 ff drum 2000m (+/-5%)
1210.5160OQFAB212 ff drum 2000m (+/-5%)
1611.5180OQFAB216 ff drum 2000m (+/-5%)
2411.5180OQFAB224 ff drum 2000m (+/-5%)

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

 

 

Colour code of fibers

123456789101112
NaturalRedGreenYellowBrownBlueVioletOrangeGrey WhiteBlackPink
131415161718192021222324
TurquoiseRed/blackGreen/blackYellow/blackBrown/blackBlue/blackViolet/blackOrange/blackGrey/blackWhite/blackPink/blackTurquoise/black

 

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1Type Approval Program - Optical Fibre Cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



QFAI 2 UNI type, loose tube, dielectric, SHF1, fire resistant IEC60331, fire retardant IEC60332-3-22 Cat.A

 

    

 

Store at : -40 to +70 °C
Install at : -5 to +50 °CBend minimum : 15 times O.D.
Operate at : -40 to +70 °CBend minimum : 10 times O.D.
Pull maximum : 3500N
Crush maximum : 4000N/100mm
Impact maximum : 20J

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.8mm up to 12 fibers, Ø3.5mm 16-24) filled with jelly, housing up to 24 fibers
Colour code : See table
Fire protection :  mica tape wrapping.
Peripheral member :  anti rodent glass yarns.
Inner sheath : red fire retardant LSZH SHF1 material, typical thickness 1.0mm.
Dielectric armour :  anti rodent glass yarns.
Outer sheath : red fire retardant, UV-resistant LSZH SHF1 material, typical thickness 1.0mm.

Marking :  APS Finland ww/mm – QFAI 2 UNI – FIBER OPTIC CABLE [Fibre type] – IEC 60331-25 [1000°C 90min] – IEC 60332-3-22 – Lot no + meter [A]

Environmental properties and Fire Performances

SHF1 : IEC 60092-360 (359)
Degree of acidity of gases :
IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)

Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25 (1000°C, 90 minutes)
Oil resistant : intermittent splash – permanent resistance available upon request
Water absorption : IEC60502
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : ASTM G 154 IEC 60068-2-5

 

Ordering and delivery information

Fiber countOuter diameter (mm)Weight (kg/km)P/NPackaging
211.0130OQFAI202 ff 1drum 2000m (+/-5%)
411.0130OQFAI204 ff 1drum 2000m (+/-5%)
811.0130OQFAI208 ff 1drum 2000m (+/-5%)
1211.0130OQFAI212 ff 1drum 2000m (+/-5%)
1612.0150OQFAI216 ff 1drum 2000m (+/-5%)
2412.0150OQFAI224 ff 1drum 2000m (+/-5%)

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

 

 

Colour code of fibers

123456789101112
NaturalRedGreenYellowBrownBlueVioletOrangeGrey WhiteBlackPink
131415161718192021222324
TurquoiseRed/blackGreen/blackYellow/blackBrown/blackBlue/blackViolet/blackOrange/blackGrey/blackWhite/blackPink/blackTurquoise/black

 

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1Type Approval Program - Optical Fibre Cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



QFAI 2 UNI type, loose tube, dielectric, SHF2, fire resistant IEC60331, fire retardant IEC60332-3-22 Cat.A

 

    

 

Store at : -40 to +70 °C
Install at : -5 to +50 °CBend minimum : 15 times O.D.
Operate at : -40 to +70 °CBend minimum : 10 times O.D.
Pull maximum : 3500N
Crush maximum : 4000N/100mm
Impact maximum : 20J

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.8mm up to 12 fibers, Ø3.5mm 16-24) filled with jelly, housing up to 24 fibers
Colour code : See table
Fire protection :  mica tape wrapping.
Peripheral member :  anti rodent glass yarns.
Inner sheath : red fire retardant LSZH SHF1 material, typical thickness 1.0mm.
Dielectric armour :  anti rodent glass yarns.
Outer sheath : red fire retardant, UV-resistant LSZH SHF2 material, typical thickness 1.0mm.

Marking :  APS Finland ww/mm – QFAI 2 UNI SHF2 – FIBER OPTIC CABLE [Fibre type] – IEC 60331-25 [1000°C 90min] – IEC 60332-3-22 – Lot no + meter [A]

Environmental properties and Fire Performances

SHF2 : IEC 60092-360 (IEC 60092-359:1987-03)
Degree of acidity of gases :
IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)

Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas :  NES 713, CEI 20-37/7
Flame retardant :  IEC 60332-1-2
Fire retardant :  IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25 (1000°C, 90 minutes)
Ozone resistant :
 DIN VDE 0472 part 805 B

Oil resistant :  IEC60811
Water absorption : IEC60502
Water penetration : IEC 60794-1-2-F5-B
UV resistant : ASTM G 154 IEC 60068-2-5

 

Ordering and delivery information

Fiber countOuter diameter (mm)Weight (kg/km)P/NPackaging
211.0140OQFAI202 ff 2drum 2000m (+/-5%)
411.0140OQFAI204 ff 2drum 2000m (+/-5%)
811.0140OQFAI208 ff 2drum 2000m (+/-5%)
1211.0140OQFAI212 ff 2drum 2000m (+/-5%)
1612.0160OQFAI216 ff 2drum 2000m (+/-5%)
2412.0160OQFAI224 ff 2drum 2000m (+/-5%)

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

 

 

Colour code of fibers

123456789101112
NaturalRedGreenYellowBrownBlueVioletOrangeGrey WhiteBlackPink
131415161718192021222324
TurquoiseRed/blackGreen/blackYellow/blackBrown/blackBlue/blackViolet/blackOrange/blackGrey/blackWhite/blackPink/blackTurquoise/black

 

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1Type Approval Program - Optical Fibre Cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



QFAI UNI MUD type (QFAB), loose tube, dielectric, SHF2-MUD, IEC60331, IEC60332-3-22 Cat.A

 

    

 

Store at : -40 to +70 °C
Install at : -5 to +50 °CBend minimum : 15 times O.D.
Operate at : -40 to +70 °CBend minimum : 10 times O.D.
Pull maximum : 2500N
Crush maximum : 3000N/100mm
Impact maximum : 10J

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.8mm up to 12 fibers, Ø3.5mm 16-24) filled with jelly, housing up to 24 fibers
Colour code : See table
Fire protection :  mica tape wrapping.
Dielectric armour :  anti rodent glass yarns.
Outer sheath : red fire retardant LSZH SHF2-MUD material, typical thickness 1.0mm.
Marking :  APS Finland ww/mm – QFAI UNI MUD (QFAB) – FIBER OPTIC CABLE [Fibre type] – IEC 60331-25 [1000°C 90min] – IEC 60332-3-22 – Lot no + meter[A]

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25 (1000°C, 90 minutes)
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
Weather resistant : ASTM G 154, EN 11507
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : ASTM G 154 IEC 60068-2-5
Cold bend & impact : CSA C22.2

Ordering and delivery information

Fiber countOuter diameter (mm)Weight (kg/km)P/NPackaging
28.060OQFAB02 ff drum 2000m (+/-5%)
48.060OQFAB04 ff drum 2000m (+/-5%)
88.060OQFAB08 ff drum 2000m (+/-5%)
128.060OQFAB12 ff drum 2000m (+/-5%)
169.570OQFAB16 ff drum 2000m (+/-5%)
249.570OQFAB24 ff drum 2000m (+/-5%)

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

 

 

Colour code of fibers

123456789101112
NaturalRedGreenYellowBrownBlueVioletOrangeGrey WhiteBlackPink
131415161718192021222324
TurquoiseRed/blackGreen/blackYellow/blackBrown/blackBlue/blackViolet/blackOrange/blackGrey/blackWhite/blackPink/blackTurquoise/black

 

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1Type Approval Program - Optical Fibre Cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



QFAI UNI type, loose tube, dielectric, SHF1, fire resistant IEC60331, fire retardant IEC60332-3-22 Cat.A

 

    

 

Store at : -40 to +70 °C
Install at : -5 to +50 °CBend minimum : 15 times O.D.
Operate at : -40 to +70 °CBend minimum : 10 times O.D.
Pull maximum : 2500N
Crush maximum : 3000N/100mm
Impact maximum : 10J

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.8mm up to 12 fibers, Ø3.5mm 16-24) filled with jelly, housing up to 24 fibers
Colour code : See table
Fire protection :  mica tape wrapping.
Dielectric armour :  anti rodent glass yarns.
Outer sheath : red fire retardant LSZH SHF1 material, typical thickness 1.0mm.
Marking :  APS Finland ww/mm – QFAI UNI – FIBER OPTIC CABLE [Fibre type] – IEC 60331-25 [1000°C 90min] – IEC 60332-3-22 – Lot no + meter[A]

Environmental properties and Fire Performances

SHF1 : IEC 60092-360 (359)
Degree of acidity of gases :
IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)

Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25 (1000°C, 90 minutes)
Oil resistant : intermittent splash – permanent resistance available upon request
Water absorption : IEC60502
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : ASTM G 154 IEC 60068-2-5

 

Ordering and delivery information

Fiber countOuter diameter (mm)Weight (kg/km)P/NPackaging
27.560OQFAI02 ff 1drum 2000m (+/-5%)
47.560OQFAI04 ff 1drum 2000m (+/-5%)
87.560OQFAI08 ff 1drum 2000m (+/-5%)
127.560OQFAI12 ff 1drum 2000m (+/-5%)
168.570OQFAI16 ff 1drum 2000m (+/-5%)
248.570OQFAI24 ff 1drum 2000m (+/-5%)

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

 

 

Colour code of fibers

123456789101112
NaturalRedGreenYellowBrownBlueVioletOrangeGrey WhiteBlackPink
131415161718192021222324
TurquoiseRed/blackGreen/blackYellow/blackBrown/blackBlue/blackViolet/blackOrange/blackGrey/blackWhite/blackPink/blackTurquoise/black

 

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1Type Approval Program - Optical Fibre Cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



QFAI UNI type, loose tube, dielectric, SHF2, fire resistant IEC60331, IEC60332-3-22 Cat.A

 

    

 

Store at : -40 to +70 °C
Install at : -5 to +50 °CBend minimum : 15 times O.D.
Operate at : -40 to +70 °CBend minimum : 10 times O.D.
Pull maximum : 2500N
Crush maximum : 3000N/100mm
Impact maximum : 10J

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.8mm up to 12 fibers, Ø3.5mm 16-24) filled with jelly, housing up to 24 fibers
Colour code : See table
Fire protection :  mica tape wrapping.
Dielectric armour :  anti rodent glass yarns.
Outer sheath : red fire retardant LSZH SHF2 cross linked material, typical thickness 1.0mm.
Marking :  APS Finland ww/mm – QFAI UNI SHF2 – FIBER OPTIC CABLE [Fibre type] – IEC 60331-25 [1000°C 90min] – IEC 60332-3-22 – Lot no + meter[A]

Environmental properties and Fire Performances

SHF2 : IEC 60092-360 (IEC 60092-359:1987-03)
Degree of acidity of gases :
IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)

Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas :  NES 713, CEI 20-37/7
Flame retardant :  IEC 60332-1-2
Fire retardant :  IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25 (1000°C, 90 minutes)
Ozone resistant :
 DIN VDE 0472 part 805 B

Oil resistant :  IEC60811
Water absorption : IEC60502
Water penetration : IEC 60794-1-2-F5-B
UV resistant : ASTM G 154 IEC 60068-2-5

Ordering and delivery information

Fiber countOuter diameter (mm)Weight (kg/km)P/NPackaging
27.560OQFAI02 ff 2drum 2000m (+/-5%)
47.560OQFAI04 ff 2drum 2000m (+/-5%)
87.560OQFAI08 ff 2drum 2000m (+/-5%)
127.560OQFAI12 ff 2drum 2000m (+/-5%)
168.570OQFAI16 ff 2drum 2000m (+/-5%)
248.570OQFAI24 ff 2drum 2000m (+/-5%)

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

 

 

Colour code of fibers

123456789101112
NaturalRedGreenYellowBrownBlueVioletOrangeGrey WhiteBlackPink
131415161718192021222324
TurquoiseRed/blackGreen/blackYellow/blackBrown/blackBlue/blackViolet/blackOrange/blackGrey/blackWhite/blackPink/blackTurquoise/black

 

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1Type Approval Program - Optical Fibre Cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



QFCI type, loose tube, armoured, SHF1, fire resistant IEC60331, fire retardant IEC60332-3-22 Cat.A

 

    

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -40 to +70 °CBend minimum : 15 times O.D.
Pull maximum : 2000N
Crush maximum : 3000N/100mm
Impact maximum : 20J
Cable weight : 240 kg/km

 

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.2mm) filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : Steel rope with LSZH sheath
Cable core : Loose tubes and fillers (when necessary) are stranded around the central member. The core is wrapped by a tape.
Inner sheath : Black SHF1 material 1.0mm thick. Nominal outer diameter 10.1mm.
Armour : Galvanized steel, bronze or tinned copper wire braid. Coverage ≥85%.
Outer jacket : Black SHF1 material 1.2mm thick. Nominal outer diameter 13.5mm.
Marking : APS Finland ww/mm – Fiber Optic Cable QF_I “fiber count and type” – SHF1 IEC60332-3-22 Cat A IEC60331-25 – lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25 (750°C, 3 hours – 1000°C, 3 hours)
Ozone resistant : upon request
Weather resistant : upon request
LSZH SHF2 : upon request
Oil resistant : intermittent splash – permanent resistance available upon request
MUD resistant : upon request
Water absorption : IEC60502
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Ordering and delivery information

Fiber countSMOM1OM1+OM2OM3OM4Packaging
2OQFCI02S21OQFCI02M11OQFCI02ME1OQFCI02M21OQFCI02M31OQFCI02M41drum 2000m (+/-5%)
4OQFCI04S21OQFCI04M11OQFCI04ME1OQFCI04M21OQFCI04M31OQFCI04M41drum 2000m (+/-5%)
6OQFCI06S21OQFCI06M11OQFCI06ME1OQFCI06M21OQFCI06M31OQFCI06M41drum 2000m (+/-5%)
8OQFCI08S21OQFCI08M11OQFCI08ME1OQFCI08M21OQFCI08M31OQFCI08M41drum 2000m (+/-5%)
12OQFCI12S21OQFCI12M11OQFCI12ME1OQFCI12M21OQFCI12M31OQFCI12M41drum 2000m (+/-5%)
24OQFCI24S21OQFCI24M11OQFCI24ME1OQFCI24M21OQFCI24M31OQFCI24M41drum 2000m (+/-5%)
48OQFCI48S21OQFCI48M11OQFCI48ME1OQFCI48M21OQFCI48M31OQFCI48M41drum 2000m (+/-5%)

Note : for tinned copper braid add “T” at the end of the P/N, for bronze braid add “B” at the end of the P/N.

 

 

Colour code of fibers 

123456789101112
BlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAqua

 

Colour code of tubes

123456789101112Fillers
BlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAquaBlack

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1Type Approval Program - Optical Fibre Cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



QFCI type, loose tube, armoured, SHF2, fire resistant IEC60331, fire retardant IEC60332-3-22 Cat.A

 

    

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -40 to +70 °CBend minimum : 15 times O.D.
Pull maximum : 2000N
Crush maximum : 3000N/100mm
Impact maximum : 20J
Cable weight : 240 kg/km

 

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.2mm) filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : Steel rope with LSZH sheath
Cable core : Loose tubes and fillers (when necessary) are stranded around the central member. The core is wrapped by a tape.
Inner sheath : Black SHF1 material 1.0mm thick. Nominal outer diameter 10.1mm.
Armour : Galvanized steel, bronze or tinned copper wire braid. Coverage ≥85%.
Outer jacket : Black SHF2 material 1.2mm thick. Nominal outer diameter 13.5mm.
Marking : APS Finland ww/mm – Fiber Optic Cable QF_I “fiber count and type” – SHF2 IEC60332-3-22 Cat A IEC60331-25 – lot + meter

Environmental properties and Fire Performances

SHF2 : IEC 60092-360 (IEC 60092-359:1987-03)
Degree of acidity of gases :
IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)

Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas :  NES 713, CEI 20-37/7
Flame retardant :  IEC 60332-1-2
Fire retardant :  IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25 (1000°C, 90 minutes)
Ozone resistant :
 DIN VDE 0472 part 805 B

Oil resistant :  IEC60811
Water absorption : IEC60502
Water penetration : IEC 60794-1-2-F5-B
UV resistant : ASTM G 154 IEC 60068-2-5

 

Ordering and delivery information

Fiber countSMOM1OM1+OM2OM3OM4Packaging
2OQFCI02S22OQFCI02M12OQFCI02ME2OQFCI02M22OQFCI02M32OQFCI02M42drum 2000m (+/-5%)
4OQFCI04S22OQFCI04M12OQFCI04ME2OQFCI04M22OQFCI04M32OQFCI04M42drum 2000m (+/-5%)
6OQFCI06S22OQFCI06M12OQFCI06ME2OQFCI06M22OQFCI06M32OQFCI06M42drum 2000m (+/-5%)
8OQFCI08S22OQFCI08M12OQFCI08ME2OQFCI08M22OQFCI08M32OQFCI08M42drum 2000m (+/-5%)
12OQFCI12S22OQFCI12M12OQFCI12ME2OQFCI12M22OQFCI12M32OQFCI12M42drum 2000m (+/-5%)
24OQFCI24S22OQFCI24M12OQFCI24ME2OQFCI24M22OQFCI24M32OQFCI24M42drum 2000m (+/-5%)
48OQFCI48S22OQFCI48M12OQFCI48ME2OQFCI48M22OQFCI48M32OQFCI48M42drum 2000m (+/-5%)

Note : for tinned copper braid add “T” at the end of the P/N, for bronze braid add “B” at the end of the P/N.

 

 

Colour code of fibers

010203040506070809101112
WhiteRedYellowGreenBlueGreyBrownBlackVioletTurquoiseOrangePink

 

Colour code of tubes

TubeType A Type B     
2 fibers4 fibers8 fibers12 fibers24 fibers48 fibers
1Red (12 fibers)Red (2 fibers)Red (2 fibers)Red (4 fibers)Red (4 fibers)Red (6 fibers)Red (12 fibers)
2Green (24 fibers)FillerGreen (2 fibers)Green (4 fibers)Green (4 fibers)Green (6 fibers)Green (12 fibers)
3Natural (36 fibers)FillerFillerFillerNatural (4 fibers)Natural (6 fibers)Natural (12 fibers)
4Natural (48 fibers)FillerFillerFillerFillerNatural (6 fibers)Natural (12 fibers)
5- (*)- (*)- (*)- (*)- (*)- (*)- (*)
6- (*)- (*)- (*)- (*)- (*)- (*)- (*)
(*) filler only in case of 6 elements design

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1Type Approval Program - Optical Fibre Cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



QFOU type, TCWB armoured, SHF2, fire resistant IEC60331, fire retardant IEC60332-3-22 Cat.A


    

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -40 to +90 °CBend minimum : 15 times O.D.
Pull maximum : 2000N
Crush maximum : 3000N/100mm
Impact maximum : 20J
Cable weight : 250 kg/km

 

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.2mm) filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : Steel rope with LSZH sheath
Cable core : Loose tubes and fillers (when necessary) are stranded around the central member. The core is wrapped by a tape.
Inner sheath : Black SHF1 material 1.0mm thick. Nominal outer diameter 10.0mm.
Armour : tinned copper wire braid. Coverage ≥85%.
Outer jacket : Black SHF2 material 1.2mm thick. Nominal outer diameter 13.5mm.
Marking : APS Finland – QFOU – FIBER OPTIC CABLE [Fibre count and type] – IEC 60331-25 [1000°C 180 min] – IEC 60332-3-22 – Lot no + meter marking – [A]

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas :  EN 50305 9.2
Flame retardant :  IEC 60332-1-2
Fire retardant :  IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25 (@750°C 3hrs < 1 dB/fiber, @1000°C 3hours < 1,5 dB/fiber)
Ozone resistant :
 IEC 60811-403

Oil, fuel and hydrocarbon resistant :  IEC60811
Water absorption : IEC60502
Water penetration : IEC 60794-1-2-F5-B
SHF2 : IEC 60092-360 (IEC 60092-359:1987-03)

UV resistant : ASTM-D-2565-16 (720 hrs, max elongation change +/-40%)
Cold bend : CSA 22/2 No.0.3-01 210.2M90 @ -40°C

 

Ordering and delivery information

Fiber countSMOM1OM1+OM2OM3OM4Packaging
2OQFOU02S2OQFOU02M1OQFOU02MEOQFOU02M2OQFOU02M3OQFOU02M4drum 2000m (+/-5%)
4OQFOU04S2OQFOU04M1OQFOU04MEOQFOU04M2OQFOU04M3OQFOU04M4drum 2000m (+/-5%)
6OQFOU06S2OQFOU06M1OQFOU06MEOQFOU06M2OQFOU06M3OQFOU06M4drum 2000m (+/-5%)
8OQFOU08S2OQFOU08M1OQFOU08MEOQFOU08M2OQFOU08M3OQFOU08M4drum 2000m (+/-5%)
12OQFOU12S2OQFOU12M1OQFOU12MEOQFOU12M2OQFOU12M3OQFOU12M4drum 2000m (+/-5%)
24OQFOU24S2OQFOU24M1OQFOU24MEOQFOU24M2OQFOU24M3OQFOU24M4drum 2000m (+/-5%)
48OQFOU48S2OQFOU48M1OQFOU48MEOQFOU48M2OQFOU48M3OQFOU48M4drum 2000m (+/-5%)
72OQFOU72S2OQFOU72M1OQFOU72MEOQFOU72M2OQFOU72M3OQFOU72M4drum 2000m (+/-5%)

 

 

 

Colour code of fibers 

123456789101112
BlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAqua

 

Colour code of tubes

123456789101112Fillers
BlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAquaBlack

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1Type Approval Program - Optical Fibre Cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.