MOG Cat.5e LAN cable F/FTP 4 pairs SHF1

  

Standards of reference and applications

IEC 60092-370Electrical installations in ships: Guidance on cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials.
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control.
CEI EN 50288-2-1Setional specification for screened cables characterised up to 100MHz
CEI EN 50289Communication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM

Type Approval

Pending

Installation Features

Store at  -40 to +70 °C
Install at  -40 to +60 °C
Operate at : -40 to +80 °C
Bend minimum : 10 times O.D.
Bend minimum : 10 times O.D.
Pull maximum : 40N

Design

Conductor : solid annealed copper AWG24
Insulation : polyethylene foam/skin, nominal diameter 1.20mm
Pair : 2 insulated conductors stranded together
Colour code : 1.White/blue  2.White/orange  3. White/green  4.White/brown
Screen 1 : aluminium/polyester or aluminium/polyester/aluminium tape over each single pair
Screen 2 : overall aluminium/polyester or aluminium/polyester/aluminium tape with overlap and drain wire
Outer jacket : grey Fire Retardant and UV Resistant SHF1 material, LSZH (nominal thickness 0.9mm)
Marking : APS Finland – ww/yy – F/FTP 4x2xAWG24 Category 5e – 100Ohm – LSZH SHF1 IEC60332-3-24 Cat.C – lot + m

Environmental properties and Fire Performances

Degree of acidity of gases :IEC 60754-1, IEC 60754-2 (pH value >/= 4.3 and Conductivity < /=10uS/mm)
Halogen acid gas :IEC 60754-1, IEC 60754-2 (Halogen acid gas emission
Smoke Emission :IEC 61034-2, EN 50268-2 (Transmittance >/= 60%)
Toxicity of evolved gas :EN 50305 9.2
Flame retardant :IEC 60332-1-2
Fire retardant :IEC 60332-3-24 Cat.C
Oil resistant :intermittent splash
UV resistant :IEC60811-2-1, ASTM-D-2565-92A

Electrical characteristics

Frequency (MHz) :1410162031.2562.5100155200
Attenuation (dB/100m)2.04.16.58.29.311.717.022.025.030.0
NEXT (dB)65.356.350.345.844.342.938.435.334.032.0
ELFEXT (dB)63.851.843.839.737.835.833.923.821.719.9
Return Loss202325252523.621.520.119.018.0
ACR (dB/100m)78.171.364.460.857.149.741.631.825.117.8

Test voltage :700 Vrms (cond/cond and cond/screen) for 1 minute
Conductor resistance :
Insulation resistance :>/= 500 MOhmxkm
Nominal Capacitance :52 pF/m (cond/cond)
Characteristic impedance :100 +/- 5 Ohm @ 100MHz
Capacitance unbalance :Min. 160 pF/100m @ 1KHz (P-to-G)

Ordering and delivery information

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairsO5EFF4P24S17.570.0drum 500m / 1000m (+/-5%)

Recommended connectivity

Keystone jack : KJ6ASTPNH
RJ45 plug : P456SAPS
Panel : PPE24SU, OPPE24SU
Patchcords : PCMJ5ES_, PCMJ6S_

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



MOG Cat.7 S/FTP 4 pairs solid conductor AWG23/1 SHF1

 

    

 

Store at: -40 to +60 °C
Install at: -40 to +60 °CBend minimum: 8 times O.D.
Operate at: -40 to +60 °CBend minimum: 10 times O.D.
Pull maximum: 100N
Cable weight: 68 kg/km

 

Design

Conductor : solid bare copper AWG23/1 
Insulation : Cellular polyolefin  (SFS-PE)
Pair : No 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Screen 1 : Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Screen 2 : overall Tinned Copper Wire Braid

Outer jacket : Grey Fire Retardant and UV Resistant SHF1 material, LSZH (nominal thickness 0.7mm)
Marking : APS Finland – ww/yy – S/FTP 4x2xAWG23/1 Cat.7 LSZHSHF1 – IEC60332-3-22 Cat A – lot + m

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Smoke emission (Transmittance) ≥ 60%)
Toxicity of evolved gas :  EN 50305 9.2
Flame retardant :  IEC 60332-1-2
Fire retardant :  IEC 60332-3-22 Cat.A
UV resistant :  ASTM-D-2565-99

 

 

Ordering and delivery information

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairsO7SF4P23S17.768500 m (+/-5%)

 

 

Electrical characteristics (IEC 60811, EN 50288-4-2)

Test voltage :  0.7kV a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 14,5 /100m
Insulation resistance : ≥ 500 MΩxkm (100V-500V)
Nominal Capacitance @ 800÷1000MHz : 45 pF/m
Average characteristic impedance : 100 ± 15 Ω @ 1-100MHz
Transfer impedance : ≤ 3mΩ/m @ 10MHz 

Frequency (MHz) :1410162031.2562.5100155200300400500600
Attenuation dB/100m (typical)1.73.25.26.57.39.413.617.022.224.330.235.239.143.5
NEXT dB (typical)105105105105105105103100989593908785
ACR dB/100m1031021009898968983767173554841
ELFEXT dB/100m (typical)9593929190868277737067646260
Return Loss dB (typical)2528303030303030282625242323

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 seriesCommunication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.




MOG Cat.7 S/FTP 4 pairs stranded conductor AWG23/7 SHF1

 

    

 

Store at: -40 to +70 °C
Install at: -40 to +70 °CBend minimum: 20 times O.D.
Operate at: -40 to +80 °CBend minimum: 15 times O.D.
Pull maximum: 100N
Cable weight: 80 kg/km

 

Design

Conductor : Stranded bare copper 7×0.22 AWG23 (0,28mm2)
Insulation : Cellular polyolefin Ø1.5mm
Pair : No 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Screen 1 : Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Screen 2 : overall Tinned Copper Wire Braid

Outer jacket : Grey Fire Retardant and UV Resistant SHF1 material, LSZH (nominal thickness 1.0mm, Ø 8.6mm)
Marking : APS Finland – ww/yy – SFTP Flex 4x2x23AWG Cat.7 SHF1 – DNV – IEC60332-3-22 Cat A – TK/lot + m

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Smoke emission (Transmittance) ≥ 60%)
Toxicity of evolved gas : YES – NES 713, CEI 20-37/7
Flame retardant : YES – IEC 60332-1-2,
Fire retardant : YES – IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : available upon request –
Weather resistant : available upon request
LSZH SHF2 : available upon request –
Oil resistant : available upon request
MUD resistant : available upon request –
Water resistant : available upon request
Water penetration : NO
UV resistant : YES – ASTM-D-2565-92A

 

 

Ordering and delivery information

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairsO7SF4P23F18.690500 m (+/-5%)

 

 

Electrical characteristics (IEC 60811, EN 50288-4-2)

Test voltage : 1kV d.c. or 0.7kV a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 69,5 /km
Insulation resistance : ≥ 500 MΩxkm (100V-500V)
Nominal Capacitance @ 800÷1000MHz : 55 pF/m
Average characteristic impedance : 100 ± 5 Ω @ 100MHz
Transfer impedance : ≤15mΩ/m @ 1MHz, – ≤10mΩ/m @ 10MHz – ≤30mΩ/m @ 30MHz

Frequency (MHz) :1410162032.562.5100155200300600
Attenuation dB/100m (typical)2.23.85.97.48.410.515.318.123.226.633.350.1
NEXT dB (typical)10010095909090858280777167
PS NEXT dB (typical)959590868080807570686662
ELFEXT dB (typical)969390100100100100100100100100
PS ELFEXT dB (typical)9890981059090909090909090
Return Loss dB (typical)353138323231273428252321

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 seriesCommunication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.




MOG Cat.7A S/FTP 4 pairs solid conductor AWG22/1 SHF1

 

    

 

Store at: -40 to +60 °C
Install at: -40 to +60 °CBend minimum: 8 times O.D.
Operate at: -40 to +60 °CBend minimum: 10 times O.D.
Pull maximum: 100N
Cable weight: 68 kg/km

 

Design

Conductor : solid bare copper AWG22/1 
Insulation : Cellular polyolefin  (SFS-PE), typical diam. 1.58 ± 0.02 mm
Pair : No 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown (IEC 708-1)
Screen 1 : Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Screen 2 : overall Tinned Copper Wire Braid

Outer jacket : Grey Fire Retardant and UV Resistant SHF1 material, LSZH

Marking : APS Finland – ww/yy – S/FTP 4x2xAWG22/1 Cat.7A LSZH SHF1 – IEC60332-3-22 Cat A – lot + m

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Smoke emission (Transmittance) ≥ 60%)
Toxicity of evolved gas :  EN 50305 9.2
Flame retardant :  IEC 60332-1-2
Fire retardant :  IEC 60332-3-22 Cat.A
UV resistant :  ASTM-D-2565-99

 

 

Electrical characteristics (IEC 60811, EN 50288-4-2)

Test voltage :  0.7kV a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 14,5 /100m
Insulation resistance : ≥ 500 MΩxkm (100V-500V)
Nominal Capacitance @ 800÷1000MHz : 45 pF/m
Average characteristic impedance : 100 ± 5 Ω @ 1-100MHz
Transfer impedance : ≤ 5mΩ/m @ 10MHz 

Frequency (MHz) :1410162031.2562.5100155200300500600
Attenuation dB/100m (typical)1.73.25.06.37.08.913.016.221.223.028.536.240.7
NEXT dB (typical)1101101101101101101101081051021009693
ACR dB/100m10810710510410310197928479716052
ELFEXT dB/100m (typical)10510310098959390858278706360
Return Loss dB (typical)25283030303030302928272625
Frequency (MHz) :100012001500
Attenuation dB/100m (typical)54.257.967.2
NEXT dB (typical)888583
ACR dB/100m342716
ELFEXT dB/100m (typical)524230
Return Loss dB (typical)242321

 

Ordering and delivery information

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairsO7ASF4P22S19.0881000 m (+/-5%)

 

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 seriesCommunication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.




MOG Cat.7A S/FTP 4 pairs stranded conductor AWG22/7 SHF1

 

    

 

Store at: -40 to +60 °C
Install at: -40 to +60 °CBend minimum: 8 times O.D.
Operate at: -40 to +60 °CBend minimum: 10 times O.D.
Pull maximum: 100N

 

Design

Conductor : stranded bare copper AWG22/7 
Insulation : Cellular polyolefin (SFS-PE), typical diam. 1.64 ± 0.03 mm
Pair : No 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown (IEC 708-1)
Screen 1 : Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Screen 2 : overall Tinned Copper Wire Braid

Outer jacket : Grey Fire Retardant and UV Resistant SHF1 material, LSZH

Marking : APS Finland – ww/yy – S/FTP 4x2xAWG22/7 Cat.7A LSZH SHF1 – IEC60332-3-22 Cat A – lot + m

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Smoke emission (Transmittance) ≥ 60%)
Toxicity of evolved gas :  EN 50305 9.2
Flame retardant :  IEC 60332-1-2
Fire retardant :  IEC 60332-3-22 Cat.A
UV resistant :  ASTM-D-2565-99
Chemical properties: RoHS 2011/95/EU, IEC60811-2-1 (IRM 902, 4h at 70 degrees C)

 

 

Electrical characteristics (IEC 60811, EN 50288-4-2)

Test voltage :  0.7kV a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 14,5 /100m
Insulation resistance : ≥ 500 MΩxkm (100V-500V)
Nominal Capacitance @ 800÷1000MHz : 45 pF/m
Average characteristic impedance : 100 ± 5 Ω @ 1-100MHz
Transfer impedance : ≤ 5mΩ/m @ 10MHz

 

Frequency (MHz) :1410162031.2562.5100155200300500600
Attenuation dB/100m (typical)1.83.35.16.47.29.113.316.521.523.428.936.541.0
NEXT dB (typical)1101101101101101101101081051021009693
ACR dB/100m10810710510410310197918378715952
ELFEXT dB/100m (typical)10510310098959390858278706360
Return Loss dB (typical)25283030303030302928272624
Frequency (MHz) :100012001500
Attenuation dB/100m (typical)54.658.467.8
NEXT dB (typical)888583
ACR dB/100m332715
ELFEXT dB/100m (typical)524230
Return Loss dB (typical)232220

 

Ordering and delivery information

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairsO7ASF4P22719.0881000 m (+/-5%)

 

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 seriesCommunication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.




MOG Cat.7 S/FTP 4 pairs stranded conductor AWG23/7 SHF2 NEK 606

     

 

Store at: -40 to +70 °C
Install at: -40 to +70 °CBend minimum: 20 times O.D.
Operate at: -40 to +80 °CBend minimum: 15 times O.D.
Pull maximum: 100N
Cable weight: 90 kg/km

 

Design

Conductor : Stranded bare copper 7×0.22 AWG23 (0,28mm2)
Insulation : Cellular polyolefin Ø1.5mm
Pair : No 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Screen : Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Inner jacket : Fire Retardant SHF1 material, LSZH (nominal thickness 0.8mm, Ø 8.2mm)
Outer jacket : Black Fire Retardant, UV and MUD Resistant SHF2 material, LSZH (nominal thickness 1.0mm, Ø 10.0mm)
Marking : APS Finland – ww/yy – SFTP Flex 4x2x23AWG Cat.7 MUD Resistant NEK606 – IEC60332-3-22 Cat A – TK/lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Smoke emission (Transmittance) ≥ 60%)
Toxicity of evolved gas : YES – EN 50305 9.2
Flame retardant : YES – IEC 60332-1-2
Fire retardant : YES – IEC 60332-3-22 Cat.A
Fire resistant : NO – IEC 60331-25
Ozone resistant : YES – DIN VDE 0472 part 805 B
Weather resistant : YES – ASTM G 154, EN 11507
LSZH SHF2 : YES – IEC 60092-359:1987-03
Oil resistant : YES (oil, fuels and hydrocarbons) – IEC60811
MUD resistant : YES – NEK 606:2009
Water resistant : YES – IEC60502
Water penetration : NO – IEC 60794-1-2-F5-B
UV resistant : YES – ASTM-D-2565-92A
Cold Bend & Impact : YES – CSA C22.2 No. 38-95

 

Ordering and delivery information

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairsO7SF4P23FU10.0130500 m (+/-5%)

 

 

Electrical characteristics (IEC 60811, EN 50288-4-2)

Test voltage : 1kV d.c. or 0.7kV a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 69,5 /km
Insulation resistance : ≥ 500 MΩxkm (100V-500V)
Nominal Capacitance @ 800÷1000MHz : 55 pF/m
Average characteristic impedance : 100 ± 5 Ω @ 100MHz
Transfer impedance : ≤15mΩ/m @ 1MHz, – ≤10mΩ/m @ 10MHz – ≤30mΩ/m @ 30MHz

Frequency (MHz) :1410162032.562.5100155200300600
Attenuation dB/100m (typical)2.23.85.97.48.410.515.318.123.226.633.350.1
NEXT dB (typical)10010095909090858280777167
PS NEXT dB (typical)959590868080807570686662
ELFEXT dB (typical)969390100100100100100100100100
PS ELFEXT dB (typical)9890981059090909090909090
Return Loss dB (typical)353138323231273428252321

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 seriesCommunication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 




MOG Cat.6 LAN cable F/FTP 4 pairs SHF1

  

Standards of reference and applications

IEC 60092-370Electrical installations in ships: Guidance on cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials.
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control.
CEI EN 50288-5-1Shielded cables for horizontal and backbone area up to 250 MHz.
CEI EN 50289Communication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, EN 50288-5/6
Applications Ethernet 10 BASE-T, 100 BASE-T, 100 BASE-TX, 155 Mbit ATM, 625 Mbit ATM, 1.2Gbit ATM

Type Approval

Pending

Installation Features

Store at  -40 to +70 °C
Install at  -40 to +60 °C
Operate at : -40 to +80 °C
Bend minimum : 10 times O.D.
Bend minimum : 10 times O.D.
Pull maximum : 40N

Design

Conductor : solid annealed copper AWG24
Insulation : polyethylene foam/skin
Pair : 2 insulated conductors stranded together
Colour code : 1.White/blue  2.White/orange  3. White/green  4.White/brown
Screen 1 : aluminium/polyester or aluminium/polyester/aluminium tape over each single pair
Screen 2 : overall aluminium/polyester or aluminium/polyester/aluminium tape with overlap and drain wire
Outer jacket : grey Fire Retardant and UV Resistant SHF1 material, LSZH (nominal thickness 0.9mm)
Marking : APS Finland – ww/yy – F/FTP 4x2xAWG24 Category 6 – 100Ohm – LSZH SHF1 IEC60332-3-24 Cat.C – lot + m

 

Environmental properties and Fire Performances

Degree of acidity of gases :IEC 60754-1, IEC 60754-2 (pH value >/= 4.3 and Conductivity < /=10uS/mm)
Halogen acid gas :IEC 60754-1, IEC 60754-2 (Halogen acid gas emission
Smoke Emission :IEC 61034-2, EN 50268-2 (Transmittance >/= 60%)
Toxicity of evolved gas :EN 50305 9.2
Flame retardant :IEC 60332-1-2
Fire retardant :IEC 60332-3-24 Cat.C
Oil resistant :intermittent splash
UV resistant :IEC60811-2-1, ASTM-D-2565-92A

Electrical characteristics

Frequency (MHz) :1410162031.2562.5100155200250300
Attenuation (dB/100m)1.83.55.46.97.87.817.521.824.929.533.0
NEXT (dB)858075706765646257555250
ELFEXT (dB)908073686663595452484644
Return Loss242730303030302826242221
ACR (dB/100m)83.276.569.663.159.255.250.144.535.230.122.517.0

Test voltage :700 V-AC
Conductor loop resistance :19 Ohm/100m
Insulation resistance :5 Ohm x km (min.)
Mutual Capacitance (nom.):50 pF/m
NVP :76%
Characteristic impedance :100 +/- 15 Ohm @ 100MHz
100 +/- 22 Ohm @ 250MHz
Screen attenuation :40dB ( <250MHz)
Transfer Impedance :30 mOhm/m (nom.)

Ordering and delivery information

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairsO6FF4P24S1D507.570.0drum 500m (+/-5%)
4 pairsO6FF4P24S1D107.570.0drum 1000m (+/-5%)

Recommended connectivity

Keystone jack : KJ6ASTPNH
RJ45 plug : P456SAPS
Panel : PPE24SU, OPPE24SU
Patchcords : PCMJ6S_

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.



MOG Cat.5e S/FTP 4 pairs AWG24/7 SHF1

    

Store at : -40 to +70 °C
Install at : -40 to +70 °C, Bend minimum : 10 times O.D.
Operate at : -40 to +80 °C, Bend minimum : 10 times O.D.
Pull maximum : 50N
Cable weight : 80 kg/km

 

Design

Conductor : stranded bare copper 7×0.20 AWG24 (0,22mm2)
Insulation : polyethylene
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Screen 1 : aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Screen 2 : tinned copper braid coverage min. 60%
Outer jacket : grey Fire Retardant and UV Resistant SHF1 material, LSZH (nominal thickness 1.0mm, Ø 8.7mm)
Marking : APS Finland – ww/yy – SFTP Flex 4x2x24AWG Cat.5e SHF1 – IEC60332-3-22 Cat A – lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Oil resistant : intermittent splash – permanent resistance available upon request
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Ordering and delivery information

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairsO5ESF4P24F18.780500 or 1000 m (+/-5%)

 

Electrical characteristics

Test voltage : 700 Vrms (cond/cond and cond/screen) for 1 minute Resistance of the conductor @ 20°C : ≤ 88 Ω/km
Insulation resistance : ≥ 500 MΩxkm
Nominal Capacitance : 52 pF/m (cond/cond)
Average characteristic impedance : 100 ± 5 Ω @ 100MHz

Frequency (MHz) :1410162031.562.5100
Attenuation (dB/100m)3.26.09.512.113.617.124.832.0
NEXT (dB)65.356.350.347.245.842.938.435.3
ELFEXT (dB)63.851.843.839.737.833.927.923.8
Return Loss23.024.125.025.025.023.621.520.1

Recommended connectivity

Keystone jack : KJ6ASTPNH
RJ45 plug : P456SAPS
Panel : OPPE24SU
Patchcords : PCMJ6S_

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 seriesCommunication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM




MOG Cat.5e S/FTP 4 pairs AWG24/7 SHF2 MUD Resistant NEK606

    

 

Store at : -40 to +70 °C
Install at : -40 to +70 °CBend minimum : 10 times O.D.
Operate at : -40 to +80 °CBend minimum : 10 times O.D.
Pull maximum : 100N
Cable weight : 130 kg/km

 

Design

Conductor : stranded bare copper 7×0.20 AWG24 (0,22mm2)
Insulation : polyethylene
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Screen 1 : aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Screen 2 : tinned copper braid coverage min. 60%
Inner jacket : grey Fire Retardant SHF1 material, LSZH (nominal thickness 1.0mm, Ø 8.7mm)
Outer jacket : black compound SHF2 and MUD resistant (nominal thickness 1.0mm, Ø 10.7mm)
Marking : APS Finland – ww/yy – SFTP Flex 4x2x24AWG Cat.5e SHF2 MUD Resistant – NEK606 – IEC60332-3-22 Cat A – lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact : CSA C22.2, UL44

 

Ordering and delivery information

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairsO5ESF4P24FU10.7130500 or 1000 m (+/-5%)

 

Electrical characteristics

Test voltage : 700 Vrms (cond/cond and cond/screen) for 1 minute
Resistance of the conductor @ 20°C : ≤ 88 Ω/km

Insulation resistance : ≥ 500 MΩxkm
Nominal Capacitance : 52 pF/m (cond/cond)
Average characteristic impedance : 100 ± 5 Ω @ 100MHz

Frequency (MHz) :1410162031.562.5100
Attenuation (dB/100m)3.26.09.512.113.617.124.832.0
NEXT (dB)65.356.350.347.245.842.938.435.3
ELFEXT (dB)63.851.843.839.737.833.927.923.8
Return Loss23.024.125.025.025.023.621.520.1

 

Recommended connectivity

Keystone jack : KJ6ASTPNH
RJ45 plug : P456SAPS
Panel : OPPE24SU
Patchcords : PCMJ6S_

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 seriesCommunication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM




MOG Cat.6 F/UTP 4 pairs AWG23/1 SHF1

    

 

Store at : -40 to +70 °C
Install at : -40 to +70 °CBend minimum : 10 times O.D.
Operate at : -40 to +70 °CBend minimum : 10 times O.D.
Pull maximum : 60N
Cable weight : 95 kg/km

 

 

Design

Conductor : solid bare copper AWG23
Insulation : polyethylene
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Assembling : no 4 pairs assembled together around a PE central cross
Screen : aluminium/mylar tape (coverage 100%) with tinned copper drain wire 0.50mm
Inner jacket : grey Fire Retardant SHF1 material (nominal Ø 7.2mm)
Outer jacket : grey or black Fire Retardant SHF1 UV-Resistant material (nominal Ø 8.6mm)
Marking : APS Finland – ww/yy – F/UTP 4x2xAWG23/1 Cat.6 SHF1 – IEC60332-3-22 Cat A – lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Oil resistant : intermittent splash – permanent resistance available upon request
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

Electrical characteristics

Test voltage : 2500 V DC for 2 minutes
Resistance of the conductor @ 20°C : ≤ 70 Ω/km
Insulation resistance : ≥ 5 GΩxkm
Nominal Capacitance : 50 pF/m (cond/cond)
Average characteristic impedance : 100 ± 5 Ω @ 100MHz


Frequency (MHz) :1410162031,562,5100155200250
Attenuation (dB/100m)2.03.86.07.68.510.815.519.924.7029.133
NEXT (dB)74.365.359.356.254.851.947.444.341.739.838.3
PS-NEXT (dB)72.363.357.354.252.849.945.442.339.737.836.3
ELFEXT (dB)67.855.847.845.941.842.042.027.824.321.820.4
PS-ELFEXT (dB)64.852.844.843.038.835.029.125.021.319.017.0
Return Loss2023.025.025.025.021.521.520.118.918.017.3

 

Ordering and delivery information

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairsO6FT4P23S18.695.0drum 500m / 1000m (+/-5%)

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 seriesCommunication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM




MOG Cat.6A S/FTP 4 pairs AWG23/7 SHF1

Store at : -0 to +50 °C
Install at : -10 to +50 °C
Bend minimum : 20 times O.D.
Operate at : -30 to +80 °C
Bend minimum : 15 times O.D.
Pull maximum : 100N
Cable weight : 80 kg/km

 

 

Design

Conductor : Stranded bare copper 7×0.22 AWG23 (0,28mm2)
Insulation : Cellular polyolefin Ø1.5mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Screen 1 : Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Screen 2 : tinned copper wire braid ce
Outer jacket : Grey RAL7035 Fire Retardant and UV Resistant SHF1 material, LSZH (nom. Ø 8.6mm)
Marking :  APS Finland – ww/yy – SFTP Flex 4x2x23AWG Cat.6A SHF1 – IEC60332-3-22 Cat A – lot + m

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Oil resistant : intermittent splash – permanent resistance available upon request
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Electrical characteristics (IEC 60811, EN 50288-4-2)

Test voltage : 0.7kV a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 69,5 /km

Insulation resistance : ≥ 500 MΩxkm
Nominal Capacitance @ 800÷1000MHz : 45 pF/m
Average characteristic impedance : 100 ± 5 Ω @ 100MHz Transfer impedance : ˂ 3mΩ/m @ 10MHz

Frequency (MHz) : 10 20 31,25 62,5 100 155 200 300 400 500 
Attenuation dB/100m (nominal) 1,8 3,3 5,4 7,4 9,6 13,9 17,5 22,4 24,8 30,7 35,9 40,2 
NEXT dB (nominal) 95 95 92 88 87 86 84 83 82 81 80 79 
ACR dB/100m (nominal) 93 92 87 81 77 72 66 61 57 50 44 39 
ELFEXT dB (nominal) 90 88 87 85 81 77 72 68 65 62 59 57 
Return Loss dB (nominal) 25 28 30 30 30 28 27 26 25 23 22 21 

 

 

Ordering and delivery information 

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairsO6ASF4P23F18.380drum 500m (+/-5%)

 

 

Recommended connectivity 

Keystone jack : KJ6ASTPNH
RJ45 plug : P456SAPS
Panel : OPPE24SU, PPE24SU
Patchcords : PCMJ6S_ 

 

 

Other standards of reference

 
IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 seriesCommunication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM

 

 




MOG Cat.6A S/FTP 4 pairs AWG23/7 SHF1 Armoured

     

 

Store at : 0 to +50 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -30 to +80 °CBend minimum : 15 times O.D.
Pull maximum : 100N

 

 

Design

Conductor : Stranded bare copper AWG23/7
Insulation : Cellular polyolefin Ø1.5mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown (IEC 708-1)
Screen 1 : Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Screen 2 : tinned copper wire braid
Inner jacket : Grey Fire Retardant SHF1 material, LSZH (nominal Ø 8.3mm)
Armour : Galvanized steel, tinned copper or bronze wire braid. Coverage ≥80%.
Outer jacket : Grey RAL7035 Fire Retardant and UV Resistant SHF1 material, LSZH (nominal thickness 1.0mm)
Marking :  APS Finland – ww/yy – ARMOURED SFTP Flex 4x2x23AWG Cat.6A SHF1 – IEC60332-3-22 Cat A – lot + m

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : upon request
Weather resistant : upon request
LSZH SHF2 : upon request
Oil resistant : intermittent splash – permanent resistance available upon request
MUD resistant : upon request
Water absorption : upon request
Water penetration : NO
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Electrical characteristics (IEC 60811, EN 50288-4-2)

Test voltage : 0.7kV a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 69,5 /km
Insulation resistance : ≥ 500 MΩxkm
Nominal Capacitance @ 800÷1000MHz : 45 pF/m Average characteristic impedance : 100 ± 5 Ω @ 100MHz
Transfer impedance : ˂ 3mΩ/m @ 10MHz

Frequency (MHz) : 10 20 31,25 62,5 100 155 200 300 400 500 
Attenuation dB/100m (nominal) 1,8 3,3 5,4 7,4 9,6 13,9 17,5 22,4 24,8 30,7 35,9 40,2 
NEXT dB (nominal) 95 95 92 88 87 86 84 83 82 81 80 79 
ACR dB/100m (nominal) 93 92 87 81 77 72 66 61 57 50 44 39 
ELFEXT dB (nominal) 90 88 87 85 81 77 72 68 65 62 59 57 
Return Loss dB (nominal) 25 28 30 30 30 28 27 26 25 23 22 21 

 

 

Ordering and delivery information 

Pair count, Armour typeP/NO.D [mm]Weight [kg/km]Packaging
4 pairs, GSWBO6ASF4P23F1A111.4140drum 500m (+/-5%)
4 pairs TCWBO6ASF4P23F1T111.4135drum 500m (+/-5%)
4 pairs, BWBO6ASF4P23F1B111.4150drum 500m (+/-5%)

 

 

Recommended connectivity 

Keystone jack : KJ6ASTPNH
RJ45 plug : P456SAPS
Panel : OPPE24SU, PPE24SU
Patchcords : PCMJ6S_ 

 

 

Other standards of reference

 
IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 seriesCommunication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.




MOG Cat.6A S/FTP 4 pairs AWG23/7 SHF2

Store at : -0 to +50 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -40 to +90 °CBend minimum : 15 times O.D.
Pull maximum : 100N
Cable weight : 80 kg/km

 

 

Design

Conductor : Stranded bare copper 7×0.22 AWG23 (0,28mm2)
Insulation : Cellular polyolefin Ø1.5mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Screen 1 : Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Screen 2 : tinned copper wire braid ce
Outer jacket :  Grey RAL7035 Fire Retardant and UV Resistant SHF2 material, LSZH (nominal Ø 8.3mm) 

Marking :  APS Finland – ww/yy – SFTP Flex 4x2x23AWG Cat.6A SHF2 – IEC60332-3-22 Cat A – lot + m

 

 

Environmental properties and Fire Performances

 Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10μS/mm) 
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%) 
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%) 
Toxicity of evolved gas : EN50305 9.2 
Flame retardant : IEC 60332-1-2 
Fire retardant : IEC 60332-3-22 Cat.A 
Fire resistant : NO 
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B 
LSZH SHF2 : IEC 60092-360 
Oil resistant : IEC60811 
MUD resistant : available upon request 
Water absorption : IEC60811-1-3 
Water penetration : NO 
UV resistant : IEC60811-2-1, ASTM-D-2565-92A 
Cold bend & impact : CSA C22.2, UL44 

 

Electrical characteristics (IEC 60811, EN 50288-4-2)

Test voltage : 0.7kV a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 69,5 /km

Insulation resistance : ≥ 500 MΩxkm
Nominal Capacitance @ 800÷1000MHz : 45 pF/m
Average characteristic impedance : 100 ± 5 Ω @ 100MHz Transfer impedance : ˂ 3mΩ/m @ 10MHz

Frequency (MHz) : 10 20 31,25 62,5 100 155 200 300 400 500 
Attenuation dB/100m (nominal) 1,8 3,3 5,4 7,4 9,6 13,9 17,5 22,4 24,8 30,7 35,9 40,2 
NEXT dB (nominal) 95 95 92 88 87 86 84 83 82 81 80 79 
ACR dB/100m (nominal) 93 92 87 81 77 72 66 61 57 50 44 39 
ELFEXT dB (nominal) 90 88 87 85 81 77 72 68 65 62 59 57 
Return Loss dB (nominal) 25 28 30 30 30 28 27 26 25 23 22 21 

 

 

Ordering and delivery information 

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairsO6ASF4P23F28.390drum 500m (+/-5%)

 

Recommended connectivity 

Keystone jack : KJ6ASTPNH
RJ45 plug : P456SAPS
Panel : OPPE24SU, PPE24SU
Patchcords : PCMJ6S_ 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 seriesCommunication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM

 

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.




MOG Cat.6A S/FTP 4 pairs AWG23/7 SHF2-MUD NEK606

    

 

Store at : -0 to +50 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -40 to +90 °CBend minimum : 15 times O.D.
Pull maximum : 100N
Cable weight : 90 kg/km

 

 

Design

Conductor : Stranded bare copper 7×0.22 AWG23 (0,28mm2)
Insulation : Cellular polyolefin Ø1.5mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Screen : Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Inner jacket : Fire Retardant SHF1 material, LSZH (nominal thickness 0.8mm, Ø 8.2mm)
Outer jacket : Black Fire Retardant, UV and MUD Resistant SHF2 material, LSZH (nominal thickness 1.0mm)
Marking :  APS Finland – ww/yy – S/FTP Flex 4x2x23AWG Cat.6A MUD Resistant NEK606 – IEC60332-3-22 Cat A – TK/lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
Water penetration : NO
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact : CSA C22.2, UL44

 

 

Electrical characteristics (IEC 60811, EN 50288-4-2)

Test voltage : 1kV d.c. or 0.7kV a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 69,5 /km
Insulation resistance : ≥ 500 MΩxkm (100V-500V)
Nominal Capacitance @ 800÷1000MHz : 45 pF/m
Average characteristic impedance : 100 ± 15 Ω @ 100MHz
Transfer impedance : ≤15mΩ/m @ 1MHz, – ≤10mΩ/m @ 10MHz – ≤30mΩ/m @ 30MHz

Frequency (MHz) : 10 20 31,25 62,5 100 155 200 300 400 500 
Attenuation dB/100m (nominal) 1,8 3,3 5,4 7,4 9,6 13,9 17,5 22,4 24,8 30,7 35,9 40,2 
NEXT dB (nominal) 95 95 92 88 87 86 84 83 82 81 80 79 
ACR dB/100m (nominal) 93 92 87 81 77 72 66 61 57 50 44 39 
ELFEXT dB (nominal) 90 88 87 85 81 77 72 68 65 62 59 57 
Return Loss dB (nominal) 25 28 30 30 30 28 27 26 25 23 22 21 

 

 

Ordering and delivery information 

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairsO6ASF4P23FU10.0130drum 500m (+/-5%)

 

Recommended connectivity 

Keystone jack : KJ6ASTPNH
RJ45 plug : P456SAPS
Panel : OPPE24SU, PPE24SU
Patchcords : PCMJ6S_ 

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 seriesCommunication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.




MOG Cat.6A S/FTP 4 pairs AWG23/7 SHF2-MUD NEK606 Armoured

    

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -40 to +90 °CBend minimum : 15 times O.D.
Pull maximum : 100N
Cable weight : 90 kg/km

 

 

Design

Conductor : Stranded bare copper 7×0.22 AWG23 (0,28mm2)
Insulation : Cellular polyolefin Ø1.5mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Screen : Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Inner jacket : Fire Retardant SHF1 material, LSZH (nominal thickness 0.8mm, Ø 8.2mm)
Armour : Galvanized steel, tinned copper or bronze wire braid. Coverage ≥80%.
Outer jacket : Black Fire Retardant, UV and MUD Resistant SHF2 material, LSZH (nominal thickness 1.0mm)
Marking :  APS Finland – ww/yy – ARMOURED SFTP Flex 4x2x23AWG Cat.6A MUD Resistant NEK606 – IEC60332-3-22 Cat A – TK/lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
Water penetration : NO
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact : CSA C22.2, UL44

 

 

Electrical characteristics (IEC 60811, EN 50288-4-2)

Test voltage : 1kV d.c. or 0.7kV a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 69,5 /km
Insulation resistance : ≥ 500 MΩxkm (100V-500V)
Nominal Capacitance @ 800÷1000MHz : 45 pF/m
Average characteristic impedance : 100 ± 15 Ω @ 100MHz
Transfer impedance : ≤15mΩ/m @ 1MHz, – ≤10mΩ/m @ 10MHz – ≤30mΩ/m @ 30MHz

Frequency (MHz) : 10 20 31,25 62,5 100 155 200 300 400 500 
Attenuation dB/100m (nominal) 1,8 3,3 5,4 7,4 9,6 13,9 17,5 22,4 24,8 30,7 35,9 40,2 
NEXT dB (nominal) 95 95 92 88 87 86 84 83 82 81 80 79 
ACR dB/100m (nominal) 93 92 87 81 77 72 66 61 57 50 44 39 
ELFEXT dB (nominal) 90 88 87 85 81 77 72 68 65 62 59 57 
Return Loss dB (nominal) 25 28 30 30 30 28 27 26 25 23 22 21 

 

 

Ordering and delivery information 

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairs, GSWBO6ASF4P23F1AU12.5160drum 500m (+/-5%)
4 pairs, BWBO6ASF4P23F1BU12.5170drum 500m (+/-5%)
4 pairs, TCWBO6ASF4P23F1TU12.5155drum 500m (+/-5%)

 

Recommended connectivity 

Keystone jack : KJ6ASTPNH
RJ45 plug : P456SAPS
Panel : OPPE24SU, PPE24SU
Patchcords : PCMJ6S_ 

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 seriesCommunication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.




MOG Cat.6A S/FTP 4 pairs solid conductor AWG23/1 SHF1

     

 

Store at : -0 to +50 °C
Install at : -10 to +50 °CBend minimum : 8 times O.D.
Operate at : -30 to +80 °CBend minimum : 4 times O.D.
Pull maximum : 100N

 

 

Design

Conductor : solid bare copper 0.575mm
Insulation : Cellular polyolefin Ø1.5mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown (IEC 708-1)
Screen 1 : Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Screen 2 : tinned copper wire braid
Outer jacket : Grey RAL7035 Fire Retardant and UV Resistant SHF1 material, LSZH (nominal Ø 8.3mm)
Marking :  APS Finland – Cat 6A LAN cable S/FTP SHF1 Unarmoured Class 1 solid conductor – DNV GL TA PROGRAMME NO.6-827.50-2 CATEGORY – IEC 61156-5 – EN 50288-1 – IEC 60332-3-24 – Batch no.- Meter marking

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : upon request
Weather resistant : upon request
LSZH SHF2 : upon request
Oil resistant : intermittent splash – permanent resistance available upon request
MUD resistant : upon request
Water absorption : upon request
Water penetration : NO
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

 

Electrical characteristics (IEC 60811, EN 50288-4-2)

Test voltage : 0.7kV a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 69,5 /km
Insulation resistance : ≥ 5GΩxkm
Nominal Capacitance @ 800÷1000MHz : 45 pF/m
Average characteristic impedance : 100 ± 15 Ω @ 100MHz Transfer impedance : ˂ 30 mΩ/m @ 10MHz

  Frequency (MHz) : 10 20 31,25 62,5 100 155 200 300 400 500 
Attenuation dB/100m (nominal) 1,9 3,5 5,6 7,9 9,8 14,2 17,8 22,1 25,1 31,0 36,4 41,8 
NEXT dB (nominal) 100 100 100 100 100 100 98 95 93 88 85 83 
ACR dB/100m (nominal) 98,1 96,5 94,4 92,1 90,2 85,8 80,2 72,9 67,9 57,0 48,6 41,2 
ELFEXT dB (nominal) 103 103 98 95 91 87 80 78 72 70 68 62 
Return Loss dB (nominal) 24 28 30 30 30 30 30 29 28 26 24 23 

 

 

Ordering and delivery information 

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairsO6ASF4P23S18.380drum 500m (+/-5%)

 

Recommended connectivity 

Keystone jack : KJ6ASTPNH
RJ45 plug : P456SAPS
Panel : OPPE24SU, PPE24SU
Patchcords : PCMJ6S_ 

 

Other standards of reference

 
IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 seriesCommunication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM

 

 

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 




MOG Cat.6A S/FTP 4 pairs solid conductor AWG23/1 SHF1, Armoured

     

 

Store at : -0 to +50 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -30 to +80 °CBend minimum : 15 times O.D.
Pull maximum : 100N

 

 

Design

Conductor : solid bare copper 0.575mm
Insulation : Cellular polyolefin Ø1.5mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown (IEC 708-1)
Screen 1 : Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Screen 2 : tinned copper wire braid
Inner jacket : Grey Fire Retardant SHF1 material, LSZH (nominal Ø 8.3mm)
Armour : Galvanized steel, tinned copper or bronze wire braid. Coverage ≥80%.
Outer jacket : Grey RAL7035 Fire Retardant and UV Resistant SHF1 material, LSZH (nominal thickness 1.0mm)
Marking : APS Finland – ww/yy – ARMOURED S/FTP Flex 4x2xAWG23/1 Cat.6A SHF1 – IEC60332-3-22 Cat A – lot + m

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Oil resistant : intermittent splash – permanent resistance available upon request
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

 

Electrical characteristics (IEC 60811, EN 50288-4-2)

Test voltage : 0.7kV a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 69,5 /km
Insulation resistance : ≥ 5GΩxkm
Nominal Capacitance @ 800÷1000MHz : 45 pF/m
Average characteristic impedance : 100 ± 15 Ω @ 100MHz Transfer impedance : ˂ 30 mΩ/m @ 10MHz

  Frequency (MHz) : 10 20 31,25 62,5 100 155 200 300 400 500 
Attenuation dB/100m (nominal) 1,9 3,5 5,6 7,9 9,8 14,2 17,8 22,1 25,1 31,0 36,4 41,8 
NEXT dB (nominal) 100 100 100 100 100 100 98 95 93 88 85 83 
ACR dB/100m (nominal) 98,1 96,5 94,4 92,1 90,2 85,8 80,2 72,9 67,9 57,0 48,6 41,2 
ELFEXT dB (nominal) 103 103 98 95 91 87 80 78 72 70 68 62 
Return Loss dB (nominal) 24 28 30 30 30 30 30 29 28 26 24 23 

 

 

Ordering and delivery information 

Pair count, Armour typeP/NO.D [mm]Weight [kg/km]Packaging
4 pairs, GSWBO6ASF4P23S1A111.4140drum 500m (+/-5%)
4 pairs TCWBO6ASF4P23S1T111.4135drum 500m (+/-5%)
4 pairs, BWBO6ASF4P23S1B111.4150drum 500m (+/-5%)

 

Recommended connectivity 

Keystone jack : KJ6ASTPNH
RJ45 plug : P456SAPS
Panel : OPPE24SU, PPE24SU
Patchcords : PCMJ6S_ 

 

Other standards of reference

 
IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 seriesCommunication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM

 

 

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 




MOG Cat.7 S/FTP 4 pairs stranded conductor AWG23/7 SHF1 Armoured

     

 

Store at : -0 to +50 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -30 to +80 °CBend minimum : 20 times O.D.
Pull maximum : 100N
Cable weight : 80 kg/km

 

Design

Conductor : Stranded bare copper 7×0.22 AWG23 (0,28mm2)
Insulation : Cellular polyolefin Ø1.5mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Screen 1 : Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Screen 2 : Tinned Copper wire braid
Inner jacket : Grey Fire Retardant and UV Resistant SHF1 material, LSZH (nominal thickness 0.8mm, Ø 8.6mm)
Armour : Galvanized steel, tinned copper or bronze braid. minimum coverage 80%.
Outer jacket :  Grey Fire Retardant and UV Resistant SHF1 material, LSZH (nominal thickness 1.0mm)
Marking : APS Finland – ww/yy – SFTP Flex 4x2x23AWG Cat.7 SHF1 – DNV – IEC60332-3-22 Cat A – TK/lot + m

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : YES – IEC 60332-1-2
Fire retardant : YES – IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : upon request
Weather resistant : upon request
LSZH SHF2 : upon request
Oil resistant : intermittent splash – permanent resistance available upon request
MUD resistant : upon request
Water absorption : upon request
Water penetration : NO
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

Ordering and delivery information

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairs, GSWBO7SF4P23F1A111.4140500 m (+/-5%)
4 pairs, BWBO7SF4P23F1B111.4150500 m (+/-5%)
4 pairs, TCWBO7SF4P23F1T111.4135500 m (+/-5%)

 

 

Electrical characteristics (IEC 60811, EN 50288-4-2)

Test voltage : 1kV d.c. or 0.7kV a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 69,5 /km
Insulation resistance : ≥ 500 MΩxkm (100V-500V)
Nominal Capacitance @ 800÷1000MHz : 55 pF/m
Average characteristic impedance : 100 ± 5 Ω @ 100MHz
Transfer impedance : ≤15mΩ/m @ 1MHz, – ≤10mΩ/m @ 10MHz – ≤30mΩ/m @ 30MHz

Frequency (MHz) :1410162032.562.5100155200300600
Attenuation dB/100m (typical)2.23.85.97.48.410.515.318.123.226.633.350.1
NEXT dB (typical)10010095909090858280777167
PS NEXT dB (typical)959590868080807570686662
ELFEXT dB (typical)969390100100100100100100100100
PS ELFEXT dB (typical)9890981059090909090909090
Return Loss dB (typical)353138323231273428252321

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 seriesCommunication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.




SCS5EU Cat.5e cable U/UTP 4 pairs AWG24/1 LSZH Indoor

   

Standards of reference and applications

ISO/IEC 11801, TIA 568-C.2, UL444, UL1581, UL1666
Ethernet 10 BASE-T, 100 BASE-T, 100 BASE-TX, 155 Mbit ATM, 625 Mbit ATM

 

Installation Features

Store at  -0 to +70 °C
Install at  -0 to +50 °C
Operate at : -10 to +60 °C
Bend minimum : 10 times O.D.
Bend minimum : 10 times O.D.
Pull maximum : 40N

 

Design

Conductor : solid bare copper AWG24 (0.50mm)
Insulation : polyethylene 0.90 ± 0.01 mm
Pair : 2 insulated conductors stranded together
Colour code : 1.White/blue  2.White/orange  3. White/green  4.White/brown
Assembling : no 4 pairs assembled together 
Outer jacket : grey LSZH material
Marking : APS Finland – ww/yy – U/UTP 4x2x24AWG Category 5e LSZH – 100Ohm – ISO/IEC 11801 – lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2
Halogen acid gas :
IEC 60754-1, IEC 60754-2
Smoke Emission :
IEC 61034-2, EN 50268-2
Toxicity of evolved gas :
EN 50305 9.2
Flame retardant :
 EN 60332-1-2

CPR Class (CE) : Class Eca

 

Electrical characteristics

Resistance of the conductor @ 20°C : ≤ 95 Ω/km
Mutual Capacitance : 50 pF/m (cond/cond)
Capacitance unbalance : 1600 pF/km (p/p @ 1KHz)
Average characteristic impedance : 100 ± 15 Ω @ 100MHz
Velocity of propagation (NVP) : 66%

Frequency (MHz) :1410162031.2562.5100155200
Attenuation (dB/100m)2.04.16.58.29.311.717.022.025.030.0
NEXT (dB)65.356.350.345.844.342.938.435.334.032.0
ELFEXT (dB)63.851.843.839.737.835.833.923.821.719.9
Return Loss202325252523.621.520.119.018.0
ACR (dB/100m)78.171.364.460.857.149.741.631.825.117.8

Ordering and delivery information

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairsW5U5042M0S305.230.5305m / 1000ft box

 

Recommended connectivity

Keystone jack : MJ5EUK 
RJ45 plug : RJ45U6PL241 / RJ45U6BL241
Panel : PPE24SU
Patchcords : PCMJ5EU_




SCS6U Cat.6 cable U/UTP 4 pairs AWG23/1 LSZH Indoor

   

Standards of reference and applications

EIA/TIA 568-C.5, ISO/IEC 11801, EN 50288-6-1
Ethernet 10 BASE-T, 100 BASE-T, 100 BASE-TX, 155 Mbit ATM, 625 Mbit ATM, 1.2 Gbit ATM

Installation Features

Store at  -0 to +70 °C
Install at  -0 to +50 °C
Operate at : -10 to +60 °C
Bend minimum : 10 times O.D.
Bend minimum : 10 times O.D.
Pull maximum : 40N

 

Design

Conductor : solid bare copper AWG23 (0.55mm)
Insulation : polyethylene 0.98 ± 0.01 mm
Pair : 2 insulated conductors stranded together
Colour code : 1.White/blue  2.White/orange  3. White/green  4.White/brown
Assembling : no 4 pairs assembled together around a PE central cross
Screen : N/A
Outer jacket : grey LSZH material
Marking : APS Finland – ww/yy – U/UTP 4x2x23AWG Category 6 LSZH – Extended Frequency 250MHz 100Ohm – ISO/IEC 11801 – /lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2
Halogen acid gas :
IEC 60754-1, IEC 60754-2
Smoke Emission :
IEC 61034-2, EN 50268-2
Toxicity of evolved gas :
EN 50305 9.2
Flame retardant :
 EN 60332-1-2

CPR Class (CE) : Class Dca

 

Electrical characteristics

Resistance of the conductor @ 20°C : ≤ 90 Ω/km
Mutual Capacitance : 52 pF/m (cond/cond)
Capacitance unbalance : 1500 pF/km (p/p @ 1KHz)
Average characteristic impedance : 100 ± 15 Ω @ 100MHz
Velocity of propagation (NVP) : 66%

Frequency (MHz) :1410162031,562,5100155200250
Attenuation (dB/100m)2.03.86.07.68.510.815.519.924.7029.133
NEXT (dB)74.365.359.356.254.851.947.444.341.739.838.3
PS-NEXT (dB)72.363.357.354.252.849.945.442.339.737.836.3
ELFEXT (dB)67.855.847.845.941.842.042.027.824.321.820.4
PS-ELFEXT (dB)64.852.844.843.038.835.029.125.021.319.017.0
Return Loss2023.025.025.025.021.521.520.118.918.017.3

Ordering and delivery information

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairsW5UX042M0S306.536.8305m / 1000ft box

 

Recommended connectivity

Keystone jack : MJ6UK / MJ6UC
RJ45 plug : RJ45U6PL241 / RJ45U6BL241
Panel : PPE24SU
Patchcords : PCMJ6U_