Energy and Electrical

Cables

Power supply and control – Industrial

POWER SUPPLY CABLES

◆ HEPR/PVC
◆ PVC/PVC
◆ XLPE/PVC
◆ EPDM/EPDM

Manufactured with the following components/features:
► Rated voltage:
        – 1,8/3 kV
        – 0,6/1 kV
► Bare or tinned copper conductor or aluminium conductor:
        – flexible stranded
        – round stranded
        – solid round
► Bare or tinned copper concentric conductor:
        – braid
        – wires
► Colour of insulation according to International Standards or on customer specification
► Shields:
        – aluminium/polyester tape with tinned copper drain wire
        – bare or tinned copper braid
        – copper wires
        – copper tapes
► Armours:
        – steel braid (aluminium for single-core cables)
        – steel wires (aluminium for single-core cables)
        – steel tapes (aluminium for single-core cables)
► Outer sheath:
        – colour according to International Standards or on customer specification
        – oil resistant
        – hydrocarbon resistant
        – chemical resistant
        – UV resistant
        – thermite resistant

POWER SUPPLY CABLES - Halogen free

◆ HEPR/LSZH
◆ EPR/LSZH
◆ XLPE/LSZH

Manufactured with the following components/features:
► Rated voltage:
        – 1,8/3 kV
        – 0,6/1 kV
► Bare or tinned copper conductor or aluminium conductor:
        – flexible stranded
        – round stranded
        – solid round
► Bare or tinned copper concentric conductor:
        – braid
        – wires
► Colour of insulation according to International Standards or on custo-
mer specification
► Shields:
        – aluminium/polyester tape with tinned copper drain wire
        – bare or tinned copper braid
        – copper wires
        – copper tapes
► Armours:
        – steel braid (aluminium for single-core cables)
        – steel wires (aluminium for single-core cables)
        – steel tapes (aluminium for single-core cables)

POWER SUPPLY CABLES - Fire resistant/circuit integrity

◆ MGT/HEPR/LSZH
◆ MGT/EPR/LSZH
◆ MGT/XLPE/LSZH

Manufactured with the following components/features:
► Rated voltage:
        – 1,8/3 kV
        – 0,6/1 kV
► Bare or tinned copper conductor or aluminium conductor:
        – flexible stranded
        – round stranded
        – solid round
► Fire resistance according to:
        – IEC 60331-21
        – CEI EN 50200 or CEI EN 50362
► Bare or tinned copper concentric conductor:
        – braid
        – wires
► Colour of insulation according to International Standards or on customer specification
► Shields:
        – aluminium/polyester tape with tinned copper drain wire
        – bare or tinned copper braid
        – copper wires
        – copper tapes
► Armours:
        – steel braid (aluminium for single-core cables)
        – steel wires (aluminium for single-core cables)
        – steel tapes (aluminium for single-core cables)
► Outer sheath:
        – colour according to International Standards or on customer specification
        – oil resistant
        – hydrocarbon resistant
        – chemical resistant
        – UV resistant
        – thermite resistant

POWER SUPPLY CABLES - Low-temperature applications

 ◆ EPDM/EPDM
◆ HEPR/PVC
◆ PVC/PVC
◆ EPR/LSZH
◆ XLPE/PVC
◆ XLPE/LSZH

Manufactured with the following components/features:
► Rated voltage:
        – 1,8/3 kV
        – 0,6/1 kV
► Bare or tinned copper conductor or aluminium conductor:
        – flexible stranded
        – round stranded
        – solid round
► Fire resistance according to:
        – IEC 60331-21
        – CEI EN 50200 or CEI EN 50362
► Bare or tinned copper concentric conductor:
        – braid
        – wires
► Colour of insulation according to International Standards or on customer specification
► Shields:
        – aluminium/polyester tape with tinned copper drain wire
        – bare or tinned copper braid
        – copper wires
        – copper tapes
► Armours:
        – steel braid (aluminium for single-core cables)
        – steel wires (aluminium for single-core cables)
        – steel tapes (aluminium for single-core cables)
► Outer sheath:
        – colour according to International Standards or on customer specification
        – PVC and LSZH sheath available in versions ARCTIC -40°C or ARCTIC -60 °C
        – oil resistant
        – hydrocarbon resistant
        – chemical resistant
        – UV resistant
        – thermite resistant

CONTROL CABLES

◆ HEPR/PVC
◆ PVC/PVC
◆ XLPE/PVC
◆ EPDM/EPDM

Manufactured with the following components/features:
► Rated voltage:
        – 0,6/1 kV
        – 450/750 V
        – 300/500 V
        – 300/300 V
► Bare or tinned copper conductor or aluminium conductor:
        – flexible stranded
        – round stranded
        – solid round
► Bare or tinned copper concentric conductor:
        – braid
        – wires
► Colour of insulation according to International Standards or on customer specification
► Shields:
        – aluminium/polyester tape with tinned copper drain wire
        – bare or tinned copper braid
        – copper wires
        – copper tapes
► Armours:
        – steel braid (aluminium for single-core cables)
        – steel wires (aluminium for single-core cables)
        – steel tapes (aluminium for single-core cables)
► Outer sheath:
        – colour according to International Standards or on customer specification
        – oil resistant
        – hydrocarbon resistant
        – chemical resistant
        – UV resistant
        – thermite resistant

CONTROL CABLES - Halogen free

◆ HEPR/LSZH
◆ EPR/LSZH
◆ XLPE/LSZH

Manufactured with the following components/features:
► Rated voltage:
        – 0,6/1 kV
        – 450/750 V
        – 300/500 V
        – 300/300 V
► Bare or tinned copper conductor or aluminium conductor:
        – flexible stranded
        – round stranded
        – solid round
► Bare or tinned copper concentric conductor:
        – braid
        – wires
► Colour of insulation according to International Standards or on customer specification
► Shields:
        – aluminium/polyester tape with tinned copper drain wire
        – bare or tinned copper braid
        – copper wires
        – copper tapes
► Armours:
        – steel braid (aluminium for single-core cables)
        – steel wires (aluminium for single-core cables)
        – steel tapes (aluminium for single-core cables)
► Outer sheath:
        – colour according to International Standards or on customer specification
        – oil resistant
        – hydrocarbon resistant
        – chemical resistant
        – UV resistant
        – thermite resistant

CONTROL CABLES - Fire resistant/circuit integrity

◆ MGT/HEPR/LSZH
◆ MGT/EPR/LSZH
◆ MGT/XLPE/LSZH

Manufactured with the following components/features:
► Rated voltage:
        – 0,6/1 kV
        – 450/750 V
        – 300/500 V
        – 300/300 V
► Bare or tinned copper conductor or aluminium conductor:
        – flexible stranded
        – round stranded
        – solid round
► Fire resistance according to:
        – IEC 60331-21
        – CEI EN 50200 or CEI EN 50362
► Bare or tinned copper concentric conductor:
        – braid
        – wires
► Colour of insulation according to International Standards or on customer specification
► Shields:
       – aluminium/polyester tape with tinned copper drain wire
       – bare or tinned copper braid
       – copper wires
       – copper tapes
► Armours:
       – steel braid (aluminium for single-core cables)
       – steel wires (aluminium for single-core cables)
       – steel tapes (aluminium for single-core cables)

CONTROL CABLES - Low-temperature applications

◆ EPDM/EPDM
◆ HEPR/PVC
◆ PVC/PVC
◆ EPR/LSZH
◆ XLPE/PVC
◆ XLPE/LSZH

Manufactured with the following components/features:
► Rated voltage:
        – 0,6/1 kV
        – 450/750 V
        – 300/500 V
        – 300/300 V
► Bare or tinned copper conductor or aluminium conductor:
        – flexible stranded
        – round stranded
        – solid round
► Fire resistance according to:
        – IEC 60331-21
        – CEI EN 50200 or CEI EN 50362
► Bare or tinned copper concentric conductor:
        – braid
        – wires
► Colour of insulation according to International Standards or on customer specification
► Shields:
        – aluminium/polyester tape with tinned copper drain wire
        – bare or tinned copper braid
        – copper wires
        – copper tapes
► Armours:
        – steel braid (aluminium for single-core cables)
        – steel wires (aluminium for single-core cables)
        – steel tapes (aluminium for single-core cables)
► Outer sheath:
        – colour according to International Standards or on customer specification
        – PVC and LSZH sheath available in versions ARCTIC -40°C or ARCTIC -60 °C
        – oil resistant
        – hydrocarbon resistant
        – chemical resistant
        – UV resistant
        – thermite resistant

EARTHING CABLES - Insulated

◆ HEPR
◆ EPR
◆ PVC

Manufactured with the following components/features:
► Rated voltage:
        – 0,6/1 kV
        – 450/750 V
        – 300/500 V
        – 300/300 V
► Bare or tinned copper conductor:
        – extra-flexible stranded
        – flexible stranded
        – round stranded
► Insulation:
        – colour according to International Standards or on customer specification
        – oil resistant
        – hydrocarbon resistant
        – UV resistant

EARTHING CABLES - Not insulated for ground connections

◆ Bare or tinned copper ropes
◆ Bare or tinned copper flat braids